Filter Registers Reference
183
SNIU028A – February 2016 – Revised April 2016
Copyright © 2016, Texas Instruments Incorporated
Filter
4.11.24 Filter Output Clamp Low Register (FILTEROCLPLO)
Address 0006005C – Filter 2 Output Clamp Low Register
Address 0009005C – Filter 1 Output Clamp Low Register
Address 000C005C – Filter 0 Output Clamp Low Register
Figure 4-29. Filter Output Clamp Low Register (FILTEROCLPLO)
17
0
OUTPUT_CLAMP_LOW
R/W-00 0000 0000 0000 0000
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 4-24. Filter Output Clamp Low Register (FILTEROCLPLO) Register Field Descriptions
Bit
Field
Type
Reset
Description
17-0
OUTPUT_CLAMP
_LOW
R/W
00 0000
0000
0000
0000
Sets the lower limit of filter output value. If calculated filter output falls below this
threshold, the filter output will be set to OUTPUT_CLAMP_LOW