Filter Registers Reference
178
SNIU028A – February 2016 – Revised April 2016
Copyright © 2016, Texas Instruments Incorporated
Filter
4.11.19 Filter KI Feedback Clamp High Register (FILTERKICLPHI)
Address 00060048 – Filter 2 KI Feedback Clamp High Register
Address 00090048 – Filter 1 KI Feedback Clamp High Register
Address 000C0048 – Filter 0 KI Feedback Clamp High Register
Figure 4-24. Filter KI Feedback Clamp High Register (FILTERKICLPHI)
23
0
KI_CLAMP_HIGH
R/W-0111 1111 1111 1111 1111 1111
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 4-19. Filter KI Feedback Clamp High Register (FILTERKICLPHI) Register Field Descriptions
Bit
Field
Type
Reset
Description
23-0
KI_CLAMP_HIGH
R/W
0111
1111
1111
1111
1111
1111
Sets the upper limit of KI_YN value. If calculated KI_YN exceeds this threshold, the
KI_YN register will be set to KI_CLAMP_HIGH