Alphabetical Summary of Debugger Messages
B-7
Debugger Messages
Corrupt call stack
Description
The debugger tried to update the CALLS window and
couldn’t. This may be because a function was called that
didn’t return. Or it could be that the program stack was over-
written in target memory. Another reason you may have this
message is that you are debugging code that has optimiza-
tion enabled (for example, you did not use the –g compile
switch); if this is the case, ignore this message—code execu-
tion is not affected.
Action
If your program called a function that didn’t return, then this is
normal behavior (as long as you intended for the function not
to return). Otherwise, you may be overwriting program
memory.
E
Error in expression
Description
This is an expression error.
Action
See Section B.3,
Additional Instructions for Expression Errors,
page B-17.
F
File does not exist
Description
The port file could not be opened for reading.
Action
Be sure that the file exists as named. If it does, enter the USE
command to identify the file’s directory.
File not found
Description
The filename specified for the FILE command was not found
in the current directory or any of the directories identified with
D_SRC.
Action
Be sure that the filename was typed correctly. If it was, reenter
the FILE command and specify full path information with the
filename.