Using the Tape Capture Web Application
Configuring the VTR Connection
171
Lightspeed Live Capture User Guide
4.
Check the
Properties
for each
USB Serial Port
to verify that its Port Settings are set
correctly to:
Bits per Second
— 9600
Data Bits
— 8
Parity
— None
Stop Bits
— 1
Flow Control
— None
5.
In
Advanced...
confirm that
Latency Timer (msec)
is set to 1. For details on adjusting
this setting, see
Configuring an RS-422 COM Port's Latency Time
in Appendix C.
6.
Verify that the SDI Input associated with the VTR has been connected to an SDI
video source.
7.
If the VTR is not connecting after performing steps 1 through 6, you can try
replacing the system cables.
After performing each step above, you can check the workflow's Monitor Status panel
to see if the Status has changed to "Initializing: VTR connected", as shown in the image
on the previous page.
When the VTR connection is successfully initialized, use the Tape Capture web app to
set recording parameters and control the VTR to ingest media from tape.
Содержание lightspeed live capture
Страница 1: ...June 2019 277130 Lightspeed Live Capture Guide Live Capture 3 0 with ComponentPac 7 2...
Страница 22: ...Contents 22...
Страница 52: ...Installing and Maintaining the Server Monitoring Lightspeed Live via SNMP 52 Lightspeed Live Capture User Guide...
Страница 196: ...Using the Tape Capture Web Application Using the Job Status View in Tape Capture 196 Lightspeed Live Capture User Guide...
Страница 208: ...Calculating Live Capture Resources Lightspeed Live Capture Resource Calculator 208 Lightspeed Live Capture User Guide...
Страница 216: ...Appendix A Support Using Log Files and Other Support Information 216 Lightspeed Live Capture User Guide...
Страница 316: ...Appendix B Containers Codecs and Vantage Actions Vantage Actions 316 Lightspeed Live Capture User Guide...