Window Search menu fields and controls.
Field or control
Description
Display
Sets the display of the mark icons on or off. If you have multiple searches defined, the control
turns off just the marks for the selected search.
Stop Acquisition if Event
Found
Stops input acquisition when the search event occurs. Default is not enabled.
Search Type
Set to Window.
Source
Lists the source channel or waveform to use to trigger or search. Types that require multiple
inputs will replace this control with a different source definition control.
Mark When
■
Enters Window: The signal outside a window enters the window defined by the upper and
lower threshold settings.
■
Exits Window: The signal exits the window defined by the upper and lower threshold
settings.
■
Inside > Limit: The signal remains inside the window longer then the specified time limit.
■
Outside > Limit: The signal remains outside the window longer then the specified time
limit.
Upper Threshold
Sets the amplitude threshold value for the upper edge of the window.
Lower Threshold
Sets the amplitude threshold value for the lower edge of the window.
Time Limit
Sets the time period condition to be met.
Only available when Mark When = Inside > Limit or Outside > Limit.
Threshold Crossing
(Trigger When = Outside >
Limit)
■
Upper: A signal remains above the upper threshold level for longer than the specified time
limit before crossing the upper threshold level to a lower level.
■
Lower: A signal remains below the lower threshold level for longer than the specified time
limit before crossing the lower threshold level to a higher level.
■
Either: A signal remains outside (above or below) the two threshold levels for longer than
the specified time limit before crossing either threshold level.
■
None: A signal remains outside the two specified threshold levels for longer than a
specified time limit.
Threshold Crossing
(Trigger When = Inside > Limit)
■
Upper: A signal remains between two thresholds for longer than the specified time limit
before crossing through the upper threshold.
■
Lower: A signal remains between two thresholds for longer than the specified time limit
before crossing through the lower threshold.
■
Either: A signal remains between two thresholds for longer than the specified time limit
before crossing through either the upper or lower threshold.
■
None: A signal remains between two threshold levels for longer than a specified time limit.
Copy Trigger Settings to
Search
Sets the search criteria to match the current oscilloscope trigger settings.
Copy Search Settings to
Trigger
Sets the current oscilloscope trigger settings to match the search criteria.
Menus and dialog boxes
MSO54, MSO56, MSO58, MSO58LP, MSO64 Help
263
Содержание 6 series
Страница 24: ...Product documents and support 4 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Страница 42: ...Options 22 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Страница 54: ...Install your instrument 34 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Страница 63: ...9 FlexChannel probe connectors Getting acquainted with your instrument MSO54 MSO56 MSO58 MSO58LP MSO64 Help 43 ...
Страница 84: ...Getting acquainted with your instrument 64 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Страница 102: ...Configure the instrument 82 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Страница 148: ...Advanced triggering 128 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Страница 154: ...Zooming on waveforms 134 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Страница 438: ...Waveform acquisition concepts 418 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Страница 448: ...Waveform display concepts 428 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Страница 483: ...Where σ is the Phase Angle Degree Measurement algorithms MSO54 MSO56 MSO58 MSO58LP MSO64 Help 463 ...
Страница 518: ...Index 498 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...