Technical Specification
Page B-4
Reference Guide: SM6610, SM6615, SM6620 and SM6625 Satellite Modulators
ST.RE.E10152.2
B.1.3 Reset/Status
Port
This connector provides volt-free relay contacts for alarm and fail, and
remote reset input.
Table B.3: Reset / Status Port Specification
Item
Specification
Safety status:
SELV
Connector designation:
RESET/STATUS
Connector type:
9-way D-type female
Alarm Contacts:
Change-over contacts (5
Ω
in common)
Fail contacts:
Change-over contacts (5
Ω
in common)
Reset contacts:
Short pins 9 and 5
B.2
DVB ASI Electrical Inputs (DVB ASI IN) –
All Base Unit Models
Two DVB ASI electrical inputs are provided as standard on each Modulator
Base Unit model. One of the two inputs is selected under user control as
the input to the Modulator.
Table B.4: DVB ASI IN Specification
Item
Specification
Safety status:
SELV
Connector type:
BNC 75
Ω
Connector designation:
ASI IN 1 and 2 (SM66XX/HWO/ASI-SPI option not fitted)
ASI IN 3 and 4 (SM66XX/HWO/ASI-SPI option fitted)
Compliance:
EN 50083-9, June 1998: Section 4.4
Input bit-rate range:
Defined by symbol rate range, modulation format, FEC code rate and input
packet size as per Table B.5, Input Bit-rate Ranges (Standard) and Table B.6,
Input Bit-rate Ranges (Extended Symbol Rate Option).
Byte stuffing modes:
Byte and Single Packet Burst modes