RS-232 Remote Control Protocol
Reference Guide: SM6610, SM6615, SM6620 and SM6625 Satellite Modulators
Page 5-11
ST.RE.E10152.2
5.3
Messages from the Modulator
5.3.1 Activate
Configuration
Table 5.12: Activate Configuration
Type
0x71
Length
1
Size
Value
Operation Success
Invalid Parameter returned if selected config empty
or not in the range 1 - 9
0x00 - Error
0x01 - OK
0x0F - Invalid Parameter
1
5.3.2 Upload
Configuration
If an error occurred when the Modulator processed the outgoing message,
the following response will occur:
Table 5.13: Upload Configuration (Error Condition)
Type
0x73
Length 1
Size
Value
Operation Success
0x00 - Error
0x0F - Invalid Parameter
1
Otherwise, the Modulator configuration is returned:
Table 5.14: Upload Configuration (Normal Condition)
Type 0x73
Length
Depends on protocol version
Size
Value
Protocol Version
0x00 - 0xFF
(See Section 5.8 Protocol Version)
1
Input
Select
Returns current input interface or test packet
source
0x00 - SPI
0x01 - ASI 1
0x03 - ASI 2
0x04 - ASI 3
0x05 - ASI 4
0x10 - Test packets (Null)
0x11 - Test packets (PRBS)
1
Reserved
Ignore
value
1
Packet Size
0x00 - 204 byte
0x01 - 188 byte
1
Reserved
Ignore
value
1
Bit-rate
Bit-rate converted from the current symbol rate in
bit/s
Byte 1: Bit-rate bits (31..24)
Byte 2: Bit-rate bits (23..16)
Byte 3: Bit-rate bits (15..8)
Byte 4: Bit-rate bits (7..0)
e.g. 0x093D1CC0 = 155 Mbit/s
4
Содержание SM6610
Страница 10: ...Introduction Page 1 2 Reference Guide SM6610 SM6615 SM6620 and SM6625 Satellite Modulators ST RE E10152 2 BLANK...
Страница 138: ...Equipment Description Page 7 2 Reference Guide SM6610 SM6615 SM6620 and SM6625 Satellite Modulators ST RE E10152 2 BLANK...
Страница 172: ...Licence Keys Page 10 2 Reference Guide SM6610 SM6615 SM6620 and SM6625 Satellite Modulators ST RE E10152 2 BLANK...