RS-232 Remote Control Protocol
Page 5-16
Reference Guide: SM6610, SM6615, SM6620 and SM6625 Satellite Modulators
ST.RE.E10152.2
5.4 Get
Status
The return below is for protocol version 4. Future expansion or changes
can be made by incrementing the protocol version number.
Table 5.22: Get Status
Type
0x77
Length 7
Size
Protocol Version
0 - 0xFF
(See Section 5.8 Protocol Version)
1
Bit 0
1
1
0..5 - Reserved
Default 0
6 - Modulation
Off
On
Modulator Status
7 - Carrier on/off
Off
On
Symbol clock offset (ppm)
Signed integer value, MSB first
2
Temperature (
°
C) Signed
byte 1
Alarm Status
Bit 0
1
1
0 - Reserved
Default 0
1 - Alarm 1
OK
Set
2 - Alarm 2
OK
Set
3 - Alarm 3
OK
Set
4 - Alarm 4
OK
Set
5 - Fail
OK
Set
6..7 Reserved
Default 0
Value
Operation Status
0x00 - Configuring
0x01 - Stand-by
0x02 - Active, Carrier On
1
5.5
Save Current Configuration
Table 5.23: Save Current Configuration
Type
0x80
Length 1
Size
Value
Operation Success
0x00 - Error
0x01 - OK
0x0F - Invalid Parameter
1