RS-232 Remote Control Protocol
Page 5-6
Reference Guide: SM6610, SM6615, SM6620 and SM6625 Satellite Modulators
ST.RE.E10152.2
5.2.4
Upload Current Configuration
Sending this message retrieves the current configuration from the
Modulator.
Table 5.5: Upload Current Configuration
Type
0x74
Length
0
5.2.5 Download
Configuration
This message downloads and activates (so becoming the current
configuration) a configuration to the Modulator. The configuration structure
can be upgraded by defining a new protocol version number and adding
the extra fields required at the end of the message.
Table 5.6: Download Configuration
Type
0x70
Length
Depends on protocol version
Size
Value
Protocol Version
0x00 - 0xFF
(See Section 5.8 Protocol Version)
1
Input Select
0x00 - SPI
0x01 - ASI 1
0x02 - Reserved
0x03 - ASI 2
0x04 - ASI 3
0x05 - ASI 4
0x10 - Test packets (Null)
0x11 - Test packets (PRBS)
1
Reserved
Set to 0x00
1
Packet Size
0x00 - 204 byte
0x01 - 188 byte
1
Reserved
Set to 0x00
1
Bit-rate
Set interface bit-rate, 1 bit/s increments. This value
is only used if Symbol rate is set to 0xFFFFFFFF.
Byte 1: Bit-rate bits (31..24)
Byte 2: Bit-rate bits (23..16)
Byte 3: Bit-rate bits (15..8)
Byte 4: Bit-rate bits (7..0)
e.g. 155 Mbit/s = 0x093D1CC0
4
Symbol
rate
Set symbol rate, 1 symbol/s increments. This value
is used by default unless set to 0xFFFFFFFF in
which case bit-rate will be used.
Byte 1: Symbol rate bits (31..24)
Byte 2: Symbol rate bits (23..16)
Byte 3: Symbol rate bits (15..8)
Byte 4: Symbol rate bits (7..0)
e.g. 30 Msymbol/s = 0x01C9C380