background image

107

Configuring the Multi-Company Variant

Multi-Company Variant

Configuring and Managing Companies

Up to five companies can be configured in the T-Comfort 930 DSL. By default, one company with the name 

“Company 1” is predefined. All configuration settings, e.g. in the user groups or in the trunk group configu-

ration, apply to this predefined default company if not other company has been selected. 

Companies are set up and managed in the 

PBX Configuration: Companies

 menu:

A new company is created in this menu using the command 

New

. Each company can be given a name up 

to 20 characters long. This name is then displayed in all configuration dialogue boxes in which company-

specific settings can be defined.

In this menu a company can be deleted again using the command 

Delete

. If a company is deleted which 

is still used at other places (in the user groups, for example), the respective configuration is changed to 

the default company.

The name of the default company can be changed, but the default company itself cannot be deleted.

Assigning Users

For each user you must define the company to which they belong. This assignment determines, for example, 

which company telephone book the user has access to and which company-specific configuration data apply 

to them.

As the T-Comfort 930 DSL manages users in groups, the assignment “user > company” is also established 

this way. The company to which each user group belongs must be defined for each group. A user group can 

only belong to one company, i.e. not to several. However, a company can have several user groups. It is 

therefore possible, in the same way as in the entire system, to allocate a range of authorisation rights for the 

use and configuration of features for each company. 

When setting up a new 

User group

 (in the 

User Manager

 menu), you will find that the default company is pre-

defined; another company can be assigned as long as no other companies have been set up.

Содержание 930 DSL

Страница 1: ...T Comfort 930 DSL Mounting and Commissioning...

Страница 2: ......

Страница 3: ...cautions 19 Mounting Location 21 Wall Mounting 21 Installing an Expansion Set 22 Installing Interface Cards 25 V 24 and Doorstation Equipment Slots 25 Slots for Additional Interface Cards 26 Available...

Страница 4: ...r Ports 43 COM Port 45 LAN Port 45 AccessoriesandAdapters 46 Upn Adapter 46 Audio Adapter 47 Device Combinations 49 Configurations without Plug in Power Supply Range up to 500 m 49 Configurations with...

Страница 5: ...ail 61 Loading SW Updates 61 Resetting the System Data 62 Basic Hardware Settings Switch 62 Generating Your Own MoH Files 63 ConfigurationExamples 65 T Comfort 930 DSL in Computer Networks 65 Introduc...

Страница 6: ...d PBX into Operation 78 Notes 79 PBXNetworking 81 Connections 81 Protocol Q SIG or DSS1 82 Master Slave 82 L1 Clock 83 Types of Point to Point Connections 84 Direct Connection 84 Connection via an Act...

Страница 7: ...Queue 99 Introduction 99 Activation of Queues 100 Call Forwarding 100 Pickup 101 Hunt Groups 101 Examples of Use 101 Enquiry Station for an Operator with Two System Telephones 101 Group of Three Enqui...

Страница 8: ...ftware 111 Setting up TAPI 111 Setting up NET CAPI 113 Using the Systray Display 114 Browser for Telefonie Assistent and Comfort Pro A Hotel 115 Setting up Video Telephony 116 Synchronising the PC Clo...

Страница 9: ...126 Branch Settings 127 E mail Function 128 E mail Access 129 FrequentlyAskedQuestions 130 General Hardware 131 Telephony 132 DECT 134 LAN 135 Internet 136 More Questions 138 TechnicalSpecifications...

Страница 10: ...8...

Страница 11: ...ards without changing the system The base module of the T Comfort 930 DSL s version 1can be expanded to connect an door entrance intercom and a serial interface For a T Comfort 930 DSL version 2 we re...

Страница 12: ...can also be connected to the DECT enabled Upn ports on interface cards An analogue port is used by standard analogue devices If the CNIP calling name identification presentation feature is supported...

Страница 13: ...SAPI 16 can also be established between several S0 interfaces of the T Comfort 930 DSL Simultaneous connections are distinguished by means of a TEI Terminal Endpoint Identifier X 31 packet data can b...

Страница 14: ...Comfort 830 handset sets up a data connection with the T Comfort 930 DSL via the DECT air interface The remainder of the connection set up is either direct through an ISDN B channel or indirect throu...

Страница 15: ...and voice information system For more information refer to the user guides called Comfort Pro A IAB integrated answering machine and Comfort Pro A IAM interactive call manager You can optimise your t...

Страница 16: ...ed on the three Upn ports Analogue terminals with the telephone numbers 10 to 13 are configured on the four a b ports The T Comfort 930 DSL is configured ready for operation in Germany Analogue device...

Страница 17: ...numbers can be dialled from all configured telephones External lines must be seized by entering a prefixed code Least cost routing is not active As soon as LCR is configured users can make calls via...

Страница 18: ...if this feature has been ordered from the network operator The white list black list and call filters are not preconfigured and thus not active If these lists are con figured they can be activated fo...

Страница 19: ...ion to system terminals is possible There are no user accounts configured for the sending of e mails the authorisation for sending e mails is not deactivated The multi company variant is not activated...

Страница 20: ...DHCP or PPP Gateway address 192 168 99 254 Domain name domain Domain name server 192 168 99 254 PPP addresses 192 168 100 0 to 192 168 100 10 DHCP addresses 192 168 99 129 to 192 168 99 148 You can ch...

Страница 21: ...are The T Comfort 930 DSL expansion set consists of One expansion module One AC adapter with a connection cable to supply the expansion module with power One mounting set with which to install the exp...

Страница 22: ...talling electrical and electronic components of the T Comfort 930 DSL Only devices that deliver safety extra low voltage SELV may be connected to the T Comfort 930 DSL Proper use of authorised devices...

Страница 23: ...ated location away from direct sources of heat Do not position the T Comfort 930 DSL in front of or above heat sources such as radiators in direct sunlight behind curtains in small unventilated damp r...

Страница 24: ...nplug the plug in power supply from the socket You should not install the expansion module or install or uninstall additional interface cards while the T Comfort 930 DSL is turned on 2 Open the housin...

Страница 25: ...Carefully press the expansion module at the top and bottom right pushing it into the locking hooks pro vided see A and B in the diagram Secure the expansion module using the Phillips screws provided i...

Страница 26: ...sh an Ethernet connection between the LAN port of the basic module and the LAN1 port of the expansion module see also Positions of the Ports starting on page 30 To do this use the short Ethernet conne...

Страница 27: ...ment Slots Slots on the basic module only T Comfort 930 DSL Version 1 The T Comfort 930 DSL Version 1 has two smaller slots in which special interface cards can be operated V 24 and doorstation equipm...

Страница 28: ...when the T Comfort 930 DSL is operational again To do this call up the PBX Configuration Ports Slots menu page The Status column in the table displays a green tick beside the name of the interface car...

Страница 29: ...aution Static charges can damage electronic components Pay attention to the regulations re garding the handling of electrostatically sensitive components 3 Carefully insert the interface card in the s...

Страница 30: ...installing the expansion set and additional interface cards see Installing an Expansion Set starting on page 22 and Installing Interface Cards starting on page 25 One S0 port to connect to an externa...

Страница 31: ...r interfaces and ports can be added by installing the expansion set and additional interface cards see Installing an Expansion Set starting on page 22 and Installing Interface Cards starting on page 2...

Страница 32: ...the basic module T Comfort 930 DSL Version 1 Position of the ports on the expansion module T Comfort 930 DSL RJ45 S01 RJ45 S02 LAN V 24 Sensor 1 2 a b 1 2 a b 3 4 S02 Upn 2 3 DC in Sensor 3 Upn1 Defa...

Страница 33: ...S0 are switchable internally externally 4 x Upn Upn are DECT enabled 8 x Upn Upn are DECT enabled 2 x S0 and 6 x Upn Upn are DECT enabled S0 are switchable internally externally 2 x S0 and 6 x a b S0...

Страница 34: ...n 1 4 Upn 1 3 Upn 1 5 Upn 1 6 Upn 1 7 Upn 1 8 Slot 1 Slot 2 Slot 3 Upn 2 1 Upn 2 2 Upn 2 3 Upn 2 4 Upn 2 5 Upn 2 6 Upn 2 7 Upn 2 8 S0 1 1 Slot 1 Slot 2 Slot 3 S0 1 2 Upn 1 1 Upn 1 2 Upn 1 3 Upn 1 4 Up...

Страница 35: ...1 4 ab 1 3 ab 2 1 ab 3 1 ab 2 2 ab 3 2 ab 2 3 ab 3 3 ab 2 4 ab 3 4 Slot 1 Slot 2 Slot 3 ab 1 1 ab 1 2 ab 1 4 ab 1 3 ab 2 1 ab 3 1 ab 2 2 ab 3 2 ab 2 3 ab 3 3 ab 2 4 ab 3 4 ab 1 5 ab 1 6 ab 1 7 ab 1 8...

Страница 36: ...in the S0 port configuration in the Configurator on the Web console You can connect up to eight terminals on every internal S0 bus up to three of the terminals can operate without an external power s...

Страница 37: ...witched between internal and external operation In contrast to the basic module the expansion module does not provide any additional RJ45 jacks for external S0 ports Therefore you can also use the pre...

Страница 38: ...00 300 500 system telephone using a twin wire cable The maximum permissible length of the twin wire cable on a Upn port is 500 m This line may only be laid inside buildings The maximum permissible len...

Страница 39: ...sor port Only use entrance intercoms and door openers complying with the German FTZ Guideline no 123D12 LAN Port The LAN port on the basic module enables integration of the T Comfort 930 DSL into an e...

Страница 40: ...IP protocol of the LAN Connecting the T Comfort 930 DSL to the network via T ISDN and T DSL Connection of the T DSL modem is via a crossover twisted pair line You can also use a switchable port on th...

Страница 41: ...in When the first external out going call is made the time and date are set to the current value as given by the exchange With the T Comfort 930 DSL Version 2 date and time generally will be adjusted...

Страница 42: ...rnally S0 ports on interface cards can also be switched external internal It is not possible to use both assignments simultaneously Up to eight devices per bus ISDN telephones ISDN fax machines ISDN b...

Страница 43: ...ports of Upn interface cards If this base station is connected to a Upn port of an interface card four simultaneous calls are possible with the handsets If the base station is connected to two Upn po...

Страница 44: ...xternal music on hold Incorrect input impedance can cause irreparable damage to the T Comfort 930 DSL Voice Mail If you are using an external voice mail system it must be capable of handling the numbe...

Страница 45: ...tering the code procedure 102 The DoorLine intercom system can be connected to any a b port However you can use only one DoorLine with the T Comfort 930 DSL For details on installing and configuring t...

Страница 46: ...am shows the usage of the PVG 402 0 module which merely serves as an example Other modules can also be operated such as its successor PVG 602 01 Door bell Siedle 12 11 9 Sensor Actor1 Actor2 a b1 Door...

Страница 47: ...0 DSL into your corporate network local area network and thus use it among other things as an IP router for accessing the Internet The LAN ports of the Ethernet switches on the expansion module proces...

Страница 48: ...al Support if you need further equipment such as headsets second handsets recording devices etc Upn Adapter The Upn adapter is an adapter with a Upn port for connecting another T Comfort 630 730 830 s...

Страница 49: ...for Socket Assignment 1 Ear cap second handset headset active speaker or micro phone RJ 10 4 pin Western socket 1 microphone 2 speaker 3 speaker 4 microphone 2 Recording device relay con tact generat...

Страница 50: ...dset headset loudspeaker Typical impedance 150 30 ohms Typical sensitivity 94 dB 1 mW 0 dB 20 Pa Active speaker Max output voltage 1 Vrms at input impedance 10 kOhms Recording device audio input Typic...

Страница 51: ...pad modules 330 mW These symbols are used in the following tables This combination is possible Reduced tone ringing open listening and hands free talking volume possible Configurations without Plug in...

Страница 52: ...Basic Unit T Comfort 830 System Telephone Add ons 2nd Terminal Power Audio adapter Upn adapter Up to 3 keypad modules 1140 mW 1470 mW 1730 mW T Comfort 630 system telephone without adapter 2335 mW T...

Страница 53: ...um power consumption of 2 2 W is not exceeded T Comfort 830 system telephone withoutadapterorkeypad module 2475 mW Basic Unit Add ons Power Audio adapter Upn adapter Up to 3 keypad modules T Comfort 7...

Страница 54: ...ystem Telephone Up to 3 key pad modules Audio adapter Upn adapter and plug in power supply T Comfort 630 without adapter T Comfort 730 without adapter T Comfort 830 without adapter and with 1 key pad...

Страница 55: ...tain system services carry out further system maintenance use PC supported telephony functions read out call charge information access the T Comfort 930 DSL telephone book The Web console has an integ...

Страница 56: ...ws 2000 XP under Start Settings Network connections Local Area Connection Open the dialogue box Local Area Connection Properties and then the dialogue box Internet Protocol TC IP Properties see figure...

Страница 57: ...a connected system telephone You can also view the net mask by en tering the procedure 183 The PC s IP address must be in this network range N Note Deactivate any connection via a proxy server which...

Страница 58: ...link with the icon configured on the desktop under step 1 Enter Admin istrator without a password as your user name 4 Start the Web browser Enter http 192 168 99 254 in the address box You will see th...

Страница 59: ...configuration PC gets its IP address automatically from the T Comfort 930 DSL or if the T Comfort 930 DSL is entered as the domain name server you can also start the Web console by entering the DNS n...

Страница 60: ...ent international external calls from the terminals for example while you are configuring the T Comfort 930 DSL and the users T Comfort 930 DSL dialogue box for initial access 5 The software opens a d...

Страница 61: ...ishing the Configuration 1 When you have completed all the settings in the Configurator you must save the configuration see also Saving and Loading the Configuration on page 60 2 Then select the Log o...

Страница 62: ...y Z zzz Set NET mask H 183 Z system PIN Z www Z xxx Z yyy Z zzz Example Enter H 1830000 192 168 99 254 If required initiate a system restart with this procedure H 1 8 5 Z system PIN Use the PIN you en...

Страница 63: ...nation of the message Further extra parameters such as the port number when a trunk line drops out are also provided The mail account for this service Account for LOG filter is configured in the Confi...

Страница 64: ...e help Proceed as follows 1 In the Configurator call up the SYS Configuration Restart menu 2 Click on Restart with Defaults 3 Confirm this by pressing OK when the query dialogue box opens Basic Hardwa...

Страница 65: ...e T Comfort 930 DSL possibly by loading a saved configuration see Saving and Loading the Configuration on page 60 Generating Your Own MoH Files The T Comfort 930 DSL comes with an internal MoH file fo...

Страница 66: ...al and external calls N Note If you don t have the Sound Recorder program or the appropriate codec on your Windows operating system you should install these components from your Windows CD Load your M...

Страница 67: ...on a PC the T Comfort 930 DSL central telephone book and your personal telephone book as well as to the company telephone book if the multi company variant is activated In addition the T Comfort 930 D...

Страница 68: ...the same and the last number is uniquely assigned to a specific device in the LAN On the Internet unique addresses assigned by a special organisation created for this purpose are used Within a LAN yo...

Страница 69: ...information on the names and IP addresses for which it is responsible For all other information a DNS server contacts other DNS servers For the establishment of every connection from the workstation...

Страница 70: ...he Configurator home page can be called up In a peer to peer network Windows network the workstations each have a name which is displayed in the network environment These NetBIOS names can differ from...

Страница 71: ...s not used in the Inter net as the domain name my firm co uk for example RAS Access You can establish a connection to the T Comfort 930 DSL from an external PC via an ISDN card The necessary IP settin...

Страница 72: ...tings via DHCP for all workstations On starting the T Comfort 930 DSL requests IP settings via DHCP If this request is responded to the T Comfort 930 DSL uses the IP settings received You can then use...

Страница 73: ...ocumentation Internet Access You can also use the T Comfort 930 DSL as an Internet access server in a LAN with an IP enabled server To do this you must enter the T Comfort 930 DSL IP address on the se...

Страница 74: ...should coordinate with the network administrator the IP address space which can be assigned to an external computer dialling in and enter it in the Configurator NET Configuration RAS ISDN menu under...

Страница 75: ...server whose address the T Comfort 930 DSL does not make known to the workstation when dialling in with ISDN For this reason you enter the address of a WINS server manually in the network settings of...

Страница 76: ...nnection after a certain period of time if no data are being transmitted Unfortunately programs other than those typically intended to access the Internet such as your browser or your e mail software...

Страница 77: ...s in the Internet is e mail E mails are buffered in individual e mail accounts on a mail server Mail servers are operated by ISPs for example With the T Comfort 930 DSL you can set up one or more e ma...

Страница 78: ...following prop erties IP addresses are transported in the useful load e g NetBIOS over TCP IP The protocol requires an active inward directed connection establishment e g ICQ The protocol will functi...

Страница 79: ...ly function like a single PBX with a higher number of ports The master PBX controls the slave PBX The fol lowing PBXs from the product family can be used for cascading Functionality of PBX Cascading P...

Страница 80: ...If necessary install the add on module for the master system If you use an T Comfort 930 DSL as the slave system you also have to install an add on module 5 Connect the two modules by means of two sui...

Страница 81: ...can see that the initialisation has been completed from the display on the system telephone connected to the slave system Notes Observe the following when operating a cascaded PBX system All Upn S0 an...

Страница 82: ...tion A memory card installed in the slave system Comfort Pro A IAB integrated answering machine cannot be used To operate the slave system again normally you must reset it to its factory settings refe...

Страница 83: ...Settings dialogue under System linking Refer also refer to the corresponding help topics in the T Comfort 930 DSL online help N Note If you do not need the features of PBX networking the simplified co...

Страница 84: ...rotocol however In par ticular the identifier indicating whether a call is internal or external cannot be transmitted using DSS1 Both protocols implement communication on several protocol layers L1 La...

Страница 85: ...han one port with the setting L1 Type Slave is configured on anT Comfort 930 DSL and the setting L1 sync possible has been activated then one of the ports is automatically defined as the L1 clock sour...

Страница 86: ...the protocol slave for all three layers Direct connection Use the RJ45 jacks on one of the external S0 ports for an S0 connection between two T Comfort 930 DSLs You can use the corresponding pressure...

Страница 87: ...the network operator or from a clock generator connected by wire Connection via the Public Network Point to point connections via the public network of a network operator can be used for bridging dis...

Страница 88: ...above example the following trunk groups are configured for PBX 1 Two S0 lines in a multi terminal configuration to the network operator which are assigned to the A trunk group Two S0 point to point...

Страница 89: ...t connection via PBX 3 the system tries again via trunk group A The prefix necessary for this can be configured with the route The user does not get a busy signal until the attempt to set up an indire...

Страница 90: ...rcular switching To avoid this a transit counter is incremented whenever a connection is switched through on Q SIG lines When the configured maximum value is reached further switching stops Technical...

Страница 91: ...configuration for the routes to be reseized t If for example you are configuring a route which can be seized using routing code 5 and have selected one or more bundles for this route change the Prefix...

Страница 92: ...required features Explanation of Keys The team functions are programmed on the call keys of the T Comfort 630 730 830 telephones Depending on the terminal different numbers of call keys are available...

Страница 93: ...at has been programmed with the same number For example the team key with the number 11 calls all trunk keys with the number 11 Busy key The purpose of a busy key is to make the busy status of other t...

Страница 94: ...a project group within a department Calls from customers of this group can then be answered by any team member who is not busy The team members can call each other by the team keys A busy key can be...

Страница 95: ...on the call number 10 trunk key TrK 10 executive s office He can also answer calls from his parallel telephone In addition a private line is configured for both of the executive s tel ephones trunk ke...

Страница 96: ...signal on one s own telephone flashing trunk key LED The parallel telephone will indicate calls only by an optical signal Time delayed acoustic signalling can be configured for TrK 10 on the secretar...

Страница 97: ...ey The team members can call each other via the team keys For example Miller can call number 12 by pressing TK 12 the call is then signalled to Smith s telephone on TrK 12 Line Busy Indication If a li...

Страница 98: ...ers can use these numbers for answering as well as making calls t In this team configuration it is useful to program one of the function keys on each tele phone with the Hold function A call e g for T...

Страница 99: ...number of call numbers can be managed efficiently with the help of team functions Each team member has one T Comfort 830 system telephone with all call keys programmed as trunk and team keys Example...

Страница 100: ...l lines e g TrK 10 and TrK 11 by pressing the appropriate key toggling Every call on a trunk key can be transferred to any other party by means of the R key For more information refer to the chapter e...

Страница 101: ...by a brief tone in the loudspeaker and in the display If calls are in the queue a number at the beginning of the second line of the display on the T Comfort 830 and Comfort Pro P 500indicates how ful...

Страница 102: ...ncoming menu Central welcoming texts can be recorded using the program package Comfort Pro A IAB integrated answering machine You should configure a new user group e g Operators and activate the autho...

Страница 103: ...s removed from all other parallel queues Examples of Use N Note Ports on a Upn interface card are DECT enabled so that DECT base stations can be connected to operate cordless system terminals Enquiry...

Страница 104: ...830 Comfort Pro P 500 which activates deactivates a call for warding immediately to the telephone number of the mobile T Comfort 830 handset Comfort Pro CM 300 in the menu Call diversion Divert phone...

Страница 105: ...onfiguration Call Distribution Incoming PTP route all incoming calls to the number of the hunt group In the Configurator create a new group called Operators under User Manager User groups Activate Cal...

Страница 106: ...In contrast to Example 1 further calls do not have to be processed after the sign off as the calls are also registered in the queues of the other signed on enquiry stations N Note The last enquiry sta...

Страница 107: ...wever It is possible to configure the T Comfort 930 DSL for each company and define the extent to which the features of the system may be used In brief the features of the multi company variant are as...

Страница 108: ...the corresponding company or its staff correctly the existing trunk groups must be uniquely assigned to the companies see Assigning Trunk Groups starting on page 108 5 In the case of outgoing externa...

Страница 109: ...example the respective configuration is changed to the default company The name of the default company can be changed but the default company itself cannot be deleted Assigning Users For each user you...

Страница 110: ...the company is irrelevant the charges are assigned according to the source principle Charges are billed to the company to which the user belongs who set up the connection The T Comfort 930 DSL recogn...

Страница 111: ...f the T Comfort 930 DSL which the users may already be familiar with from the single company variant are available in the multi company variant These features can be used to the same extent and can be...

Страница 112: ...his authorisation is useful if members of this group e g the Administrators service the entire system Foreign telephone books can only be edited in the Configurator in the Phone Book menu The number o...

Страница 113: ...Follow the program instructions Further instructions for various options that are available are given below Setting up TAPI With a TAPI Telephony Application Programming Interface you can operate a C...

Страница 114: ...s for the user who is currently logged on Click on New 5 In the following dialogue you provide information for the new connection In the Connection name box you can enter a descriptive name for the co...

Страница 115: ...e Connections component Setting up NET CAPI With a CAPI driver common application programming interface Windows programmes are able to access services and functions of an ISDN card With a network base...

Страница 116: ...ch you configured the CAPI telephone number in the User Manager see Step 3 You will find further information on the working of the NET CAPI driver and CAPI application programmes on the product CD Not...

Страница 117: ...onfig uration dialogue Select Network Connections or Trunk Lines to produce a status dia logue Browser for Telefonie Assistent and Comfort Pro A Hotel You can simplify the daily use of the Telefonie A...

Страница 118: ...g is already pre installed on the Microsoft Windows 2000 and XP operating systems Set up Microsoft NetMeeting 3 0 1 Connect a standard web cam to the workplace computer and install the driver 2 In the...

Страница 119: ...e T Comfort 930 DSL as an SNTP server for such programmes SNTP with Windows 2000 Here you configure the SNTP server as follows 1 Log on as the administrator Start the Command Prompt under Start Progra...

Страница 120: ...x will then open 2 Click on Add Select the Directory Service command from the pop up menu The Internet Connection Wizard dialogue box for Internet access will then open 3 Under Internet directory LDAP...

Страница 121: ...Upn Ports starting on page 36 2 Configure the T Comfort 730 DECT base station in the Configurator using the PBX Configuration Ports Upn menu 3 Install the software of the T Sinus 61data T Sinus 620da...

Страница 122: ...Internet access in the T Comfort 930 DSL Configurator menu NET Configuration WAN You can edit create suitable filter lists for the Internet access in the NET Configuration Firewall menu 9 Configure t...

Страница 123: ...uring ports and terminals Configuring Easy Access This chart guides you through TCP IP settings for the T Comfort 930 DSL Configuring ISP Settings These instructions support you in configuring the Int...

Страница 124: ...e user groups and users Set the system data Select the access type Connect the S0 Upn and analogue devices and configure them Configure the call distribution scheme User Manager PBX Configuration Save...

Страница 125: ...n S0 interface Do you want to operate system telephones or DECT terminals Do you want to operate analogue terminals e g a fax machine Do you want to use a sensor contact e g for a door opener Do you w...

Страница 126: ...erver Do you have a DHCP server in your network Do you have a computer network Enter the address range for the RAS accesses Gateway address DHCP adresses Domain name Client computers are informed of t...

Страница 127: ...er list IN Filter list OUT Finished Gateway Yes No No Yes Configure T Online in NET Configu ration WAN Provider You will obtain the access data when you register Enter your provider s dial in data Spe...

Страница 128: ...rights Select the filter lists Filter lists are created in NET Configuration Firewall Specify how many simultaneous connections are possible via this access Select from PAP CHAP and CLID Activate the...

Страница 129: ...number Enter the local IP address Enter the local network mask Specify the user name with which the remote LAN can access a destination Specify the password with which the remote LAN can access a dest...

Страница 130: ...onfiguration E Mail Access Have you made the network settings for the T Comfort 930 DSL Do you want to use e mail from the Internet Has an internal e mail server been configured in your LAN Do you wan...

Страница 131: ...onfiguration LAN or NET Configuration WAN User Manager User Accounts No No Yes Yes Do you have access to a mail server in your network or in the Internet Do you have created mail account polls in the...

Страница 132: ...nce with the T Comfort 930 DSL S Please note Repairs to the T Comfort 930 DSL should only be carried out by quali fied personnel The following LEDs indicate that the T Comfort 930 DSL is ready for ope...

Страница 133: ...and the plug in power supply from the socket Take the housing cover off Is the Power Fine LED illuminated If not contact your service centre The AC adapter plug of the T Comfort 930 DSL may be defecti...

Страница 134: ...to seize a trunk line Deactivate the corresponding S0 port in the Configurator PBX Configuration S0 menu One of the telephones is not functioning at all Make sure the telephone has been properly conne...

Страница 135: ...ts S0 menu must also be configured as an MSN on the ISDN telephone itself For further information refer to the User Guide of your ISDN tele phone An ISDN telephone always rings if another telephone on...

Страница 136: ...ort 830 Comfort Pro CB 300 base stations are installed the blinking LED indicates that synchronisation is not fin ished The LED of the T Comfort 830 Comfort Pro CB 300 is continuously lit up but one o...

Страница 137: ...nstalled an add on module also check the LAN LEDs of the Ethernet switch The Ethernet line between the basic module LAN port and the add on module LAN1 port are properly con nected if the centre LED l...

Страница 138: ...erent seg ments you can enter extra static routes in the NET Configuration LAN Routes menu In our network the T Comfort 930 DSL dynamically issues the IP addresses by DHCP Can I firmly assign the IP a...

Страница 139: ...Internet connection must also be specified in the respective user profile Configurator User Manager User menu With the T Comfort 830 handset the Internet can be accessed either directly via the remot...

Страница 140: ...een granted RAS access rights Configu rator User Manager User Groups menu For information on the installation of software and on configuring Internet access refer to the T Comfort 830 handset s user g...

Страница 141: ...module and power supply unit 1 900 g Add on module and power supply unit 1 000 g S0 ports Euro ISDN external S0 external for basic access DSS1 protocol Basic module 1x Add on module Euro ISDN switchab...

Страница 142: ...4 x Upn 8 x Upn 2 x S0 and 6 x Upn Supply voltage 40 V 10 Supply power 3 VA per Upn bus Range 1000 m a b port for analogue terminals with pulse or DTMF dialling flash duration of 60 to 310 ms Basic m...

Страница 143: ...limits that should be observed when configuring the T Comfort 930 DSL Doorstation equipment module for connection of doorstation equipment Basic module 1x optional Contact load of actor 2 A 125 V Volt...

Страница 144: ...re updates 61 Remote configuration 59 Resetting the system data 62 Saving and loading the configuration 60 System prerequisites 54 via V 24 port 10 Configuration examples 65 Introduction to TCP IP 66...

Страница 145: ...basic setting switch 62 I Installation 19 Mounting location 21 Ports 28 Scope of delivery 19 Wall mounting 21 Intercom system 42 Interface cards 25 Interface cards installation 27 Interface cards ove...

Страница 146: ...uipment 28 LAN 45 LAN basic module 24 29 LAN1 24 S0 28 29 Upn 28 29 V 24 29 45 Ports see Interfaces 34 Power failure 39 Q Q SIG 82 R Remote configuration 59 Resetting system data 62 Routes 87 S S0 por...

Страница 147: ...2 Terminating resistor 34 Three member team 94 Time zone 117 Toggle team 97 Troubleshooting 130 Trunk key 91 T Sinus 61 data 119 T Sinus 620 data 119 U Unified team 96 Upn port pin assignment 36 Upn p...

Страница 148: ...146 Index Notes...

Страница 149: ...147 Index Notes...

Страница 150: ...148 Index Notes...

Страница 151: ......

Страница 152: ...As of 01 09 2006 Deutsche Telekom AG T Com Bereich Endger te Postfach 20 00 53105 Bonn...

Отзывы: