7.2 C
HECKING POWER
–
B
ATTERY
The
Battery
position allows you to check the condition of the internal battery
and the voltage of the external power source. The instrument can be powered
from four AA rechargeable batteries or standard alkaline batteries or from an
external DC power supply (via the SA 33 power adapter or via the USB port).
When the instrument is powered from a set
of internal batteries you should select the
correct
battery
type
(
Alkaline
or
Rechargeable
). It is essential for the right
detection of the capacity of the battery pack.
7.3
B
LUETOOTH
®
ACTIVATION
–
B
LUETOOTH
The
Bluetooth
position becomes active
after activation of Bluetooth
®
in the
Communication Ports
screen and allows
you to enter an authorization code to pair a
PC (tablet or smartphone) with the
instrument.
To use the
Bluetooth
®
interface, you should
key in the
Authorisation code
to pair
another device with the instrument.
<ENT>
If
Visible
is enabled, the instrument will be visible during searching of Bluetooth units by other devices. The
instrument can communicate also with inactive
Visible
parameter.
If
Transf. on stop only
is enabled, the Bluetooth function is switched off during the measurement. Active
Bluetooth
®
may be a source of additional internal electrical noise in a very low acoustic environment.
7.4
I
NTERFACE PARAMETERS SETTINGS
–
C
OMMUNICATION
P
ORTS
The
Communication Ports
position
enables selecting the active communication
port of the instrument.
You can select the following combinations:
−
USB Host
/
Bluetooth
/
GPS Device Port
,
−
RS232
/
GPS Device Port
,
−
GPS Host Port
/
Bluetooth
.
<ENT>
The
USB Host
socket can be used as the input of the different interfaces:
RS 232
or
USB
. The
RS 232
interface
in SVAN 979 is available as a hardware option (a special
SV 55
interface/converter with dedicated
microprocessor has to be attached to the
USB Host
socket).
Note: The SV 55 converter serves as the RS 232 interface. The SV 55 connection to the USB Host
socket is detected and after successful detection the “RS232” icon changes its colour to blue.
Transmission with the SV 55 interface is only possible if the instrument is not connected to a PC
through the USB Device port.
The USB host interface can be used to control an external USB memory disk with the FAT16 or FAT32 file
systems. Switch on the
USB Host
position after USB disc connection.
Содержание SVAN 979
Страница 272: ...272 SVAN 979 User Manual Appendixes 400 Hz 500 Hz 630 Hz 800 Hz 1000 Hz 1250 Hz ...
Страница 273: ...273 SVAN 979 User Manual Appendixes 1600 Hz 2000 Hz 2240 Hz 2500 Hz 2800 Hz 3150 Hz ...
Страница 274: ...274 SVAN 979 User Manual Appendixes 3550 Hz 4000 Hz 4500 Hz 5000 Hz 5600 Hz 6300 Hz ...
Страница 275: ...275 SVAN 979 User Manual Appendixes 7100 Hz 8000 Hz 8500 Hz 9000 Hz 9500 Hz 10000 Hz ...
Страница 302: ...302 SVAN 979 User Manual Appendixes 8 0 kHz 1 1 octave filter 4 0 kHz 1 1 octave filter 2 0 kHz 1 1 octave filter ...
Страница 303: ...303 SVAN 979 User Manual Appendixes 1 0 kHz 1 1 octave filter 500 Hz 1 1 octave filter 250 Hz 1 1 octave filter ...
Страница 304: ...304 SVAN 979 User Manual Appendixes 125 Hz 1 1 octave filter 63 0 Hz 1 1 octave filter 31 5 Hz 1 1 octave filter ...
Страница 305: ...305 SVAN 979 User Manual Appendixes 16 0 Hz 1 1 octave filter 8 00 Hz 1 1 octave filter 4 00 Hz 1 1 octave filter ...
Страница 306: ...306 SVAN 979 User Manual Appendixes 2 00 Hz 1 1 octave filter 1 00 Hz 1 1 octave filter Summary curve ...
Страница 312: ...312 SVAN 979 User Manual Appendixes Summary curve ...
Страница 348: ...348 SVAN 979 User Manual Appendixes 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz ...
Страница 349: ...349 SVAN 979 User Manual Appendixes 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz ...
Страница 350: ...350 SVAN 979 User Manual Appendixes 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz ...
Страница 351: ...351 SVAN 979 User Manual Appendixes 5600 Hz 6300 Hz 7100 Hz 8000 Hz 8500 Hz 9000 Hz ...
Страница 352: ...352 SVAN 979 User Manual Appendixes 9500 Hz 10000 Hz 10600 Hz 11200 Hz 11800 Hz 12500 Hz ...
Страница 370: ...370 SVAN 979 User Manual Appendixes O ring gasket locations inside ...