Time of measurement start
The
Start Hour
position determines the time
for the measurement to start. The required
hour and minute can be selected in a special
screen, which is opened with the
◄ / ► key.
To set hours or minutes, select the left or
right field with the
◄ / ► key and then select
the proper value with the
▲ / ▼ key and
press
<ENTER>
to confirm settings.
►
Day of measurement start
The
Start Day
position determines the date
for the measurement to start. The timer can
be programmed up to one month ahead.
The required date can be selected in a
special screen, which is opened with the
◄ / ► key.
To set the date, select its position with the
◄ / ► or ▲ / ▼ key and then press
<ENTER>
.
►
Period between two consecutive
measurement starts
The
Repetition
position is displayed when
the
Multiple
mode is selected. This
parameter can be programmed in the range
from
00:00
up to
96:00
. The required date
can be selected in a special screen, which is
opened with the
◄ / ► key same way as
Start Hour
.
►
Note: The Timer function can be used for multiple measurements (at the programmed day and time
with the selected repetition number). The first start of the instrument must be within one month
ahead. Make sure that the RTC is configured correctly before setting up the Timer.
Note: Make sure that there is sufficient power available for the instrument to carry out the required
measurement when it wakes up and starts measurements.
4.11.1
Example of timer execution
Let us assume that the you wish to switch on the instrument on 14th of
September at 3 am, measure noise for 1 minute and save the results in a file
named
L1
.
To do this set the
Timer
parameters, set the measurement parameters (
path:
<Menu> / Measurement / General Settings
), name the file (
path: <Menu> /
Measurement / Logger / Logger Setup
) as on the attached screens and finally
– switch off the instrument.
The instrument will be switched on 14th of September at 2:59 and will be
warmed up for the period of 60 seconds decrementing the counter visible on
the display by one after each second.
After warming up and the pre-set
Start Delay
time, the measurements will be
performed by a period of one minute. Then, results will be saved in the
previously named file and finally
– the instrument will turn itself off.
Содержание SVAN 979
Страница 272: ...272 SVAN 979 User Manual Appendixes 400 Hz 500 Hz 630 Hz 800 Hz 1000 Hz 1250 Hz ...
Страница 273: ...273 SVAN 979 User Manual Appendixes 1600 Hz 2000 Hz 2240 Hz 2500 Hz 2800 Hz 3150 Hz ...
Страница 274: ...274 SVAN 979 User Manual Appendixes 3550 Hz 4000 Hz 4500 Hz 5000 Hz 5600 Hz 6300 Hz ...
Страница 275: ...275 SVAN 979 User Manual Appendixes 7100 Hz 8000 Hz 8500 Hz 9000 Hz 9500 Hz 10000 Hz ...
Страница 302: ...302 SVAN 979 User Manual Appendixes 8 0 kHz 1 1 octave filter 4 0 kHz 1 1 octave filter 2 0 kHz 1 1 octave filter ...
Страница 303: ...303 SVAN 979 User Manual Appendixes 1 0 kHz 1 1 octave filter 500 Hz 1 1 octave filter 250 Hz 1 1 octave filter ...
Страница 304: ...304 SVAN 979 User Manual Appendixes 125 Hz 1 1 octave filter 63 0 Hz 1 1 octave filter 31 5 Hz 1 1 octave filter ...
Страница 305: ...305 SVAN 979 User Manual Appendixes 16 0 Hz 1 1 octave filter 8 00 Hz 1 1 octave filter 4 00 Hz 1 1 octave filter ...
Страница 306: ...306 SVAN 979 User Manual Appendixes 2 00 Hz 1 1 octave filter 1 00 Hz 1 1 octave filter Summary curve ...
Страница 312: ...312 SVAN 979 User Manual Appendixes Summary curve ...
Страница 348: ...348 SVAN 979 User Manual Appendixes 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz ...
Страница 349: ...349 SVAN 979 User Manual Appendixes 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz ...
Страница 350: ...350 SVAN 979 User Manual Appendixes 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz ...
Страница 351: ...351 SVAN 979 User Manual Appendixes 5600 Hz 6300 Hz 7100 Hz 8000 Hz 8500 Hz 9000 Hz ...
Страница 352: ...352 SVAN 979 User Manual Appendixes 9500 Hz 10000 Hz 10600 Hz 11200 Hz 11800 Hz 12500 Hz ...
Страница 370: ...370 SVAN 979 User Manual Appendixes O ring gasket locations inside ...