![Svantek SVAN 979 Скачать руководство пользователя страница 128](http://html.mh-extra.com/html/svantek/svan-979/svan-979_user-manual_1409285128.webp)
128
SVAN 979 User Manual
14.4 STIPA
MEASUREMENT AND CALCULATION PROCESS
STI measurements usually relate to objects (buildings), which may consist of several areas (rooms) in which
measurements are made in a given number of points (in practice, from 1 up to several dozen). In addition,
especially in case of assessing speech intelligibility in a room on the directly, i.e. without an amplification
system, tests are performed for a given number of source positions (in practice from one to several). It may
happen that a given area is examined in several configurations - e.g. a theatre hall with a raised and lowered
curtain, or a rail vehicle at a standstill and while moving. The result for a given point is obtained on the basis
of several measurements (in practice from 1 to 6) - most often as an average value. Analyses are performed
independently for areas in a given configuration.
14.4.1
Measured results
The
STIPA
function enables measuring and calculating the next results:
•
STI
-
Speech Transmission Index
representing the transmission quality of speech with respect to
intelligibility by a speech transmission channel, ranging between 0 and 1. STI is calculated for
individual measurements and averaged for the measurement point and for the area.
•
Δ
– difference between maximum and minimum values of STI index obtained for the measurement
point of the tested area.
•
LAeq
– A weighed time-averaged sound level for 15-seconds integration period, in dB.
•
LCeq
– C weighed time-averaged sound level for 15-seconds integration period, in dB.
•
LZeq
– Z weighed time-averaged sound level for 15-seconds integration period, in dB.
•
LAS
– time weighted sound level expressed at observation time (15-seconds integration period), in dB.
•
m(f1), m(f2)
-
modulation transfer ratios as a function for two modulation frequency per each of
7 octave bands, ranging between 0 and 1.
•
CIS
- Common Intelligibility Scale
𝐶𝐼𝑆 = 1 + 𝑙𝑜𝑔(𝑆𝑇𝐼)
.
•
σ
- standard deviation
of measured STI indexes for the tested area.
•
Min
– minimal STI value obtained within measurements.
There are some additional indications:
•
The STI qualification band:
A+
trough
U
(see Annex G to IEC 60268-16:2011).
•
Errors detected during measurements and calculation of STI indexes.
These results are displayed in different views:
•
Area
view
- main STIPA view that allows you to create new measurement points, delete measurement
points or exclude them from the calculation of averaged indexes for the Area as well as to go to the
Point
view for the selected point. This view presents a list of measurement points and next results:
o
Averaged
STI (or CIS) index with consideration of the Ambient
noise distortions (
Avg.
) and STI spread (
Δ
) for the tested area
.
o
Averaged
STI (or CIS) indexes with consideration of the Ambient
noise distortions (
STI
) and STI spreads (
Δ
) for measurement
points.
o
The STI qualification band (
A+
through
U
) and error indication is
displayed for each measurement point.
Содержание SVAN 979
Страница 272: ...272 SVAN 979 User Manual Appendixes 400 Hz 500 Hz 630 Hz 800 Hz 1000 Hz 1250 Hz ...
Страница 273: ...273 SVAN 979 User Manual Appendixes 1600 Hz 2000 Hz 2240 Hz 2500 Hz 2800 Hz 3150 Hz ...
Страница 274: ...274 SVAN 979 User Manual Appendixes 3550 Hz 4000 Hz 4500 Hz 5000 Hz 5600 Hz 6300 Hz ...
Страница 275: ...275 SVAN 979 User Manual Appendixes 7100 Hz 8000 Hz 8500 Hz 9000 Hz 9500 Hz 10000 Hz ...
Страница 302: ...302 SVAN 979 User Manual Appendixes 8 0 kHz 1 1 octave filter 4 0 kHz 1 1 octave filter 2 0 kHz 1 1 octave filter ...
Страница 303: ...303 SVAN 979 User Manual Appendixes 1 0 kHz 1 1 octave filter 500 Hz 1 1 octave filter 250 Hz 1 1 octave filter ...
Страница 304: ...304 SVAN 979 User Manual Appendixes 125 Hz 1 1 octave filter 63 0 Hz 1 1 octave filter 31 5 Hz 1 1 octave filter ...
Страница 305: ...305 SVAN 979 User Manual Appendixes 16 0 Hz 1 1 octave filter 8 00 Hz 1 1 octave filter 4 00 Hz 1 1 octave filter ...
Страница 306: ...306 SVAN 979 User Manual Appendixes 2 00 Hz 1 1 octave filter 1 00 Hz 1 1 octave filter Summary curve ...
Страница 312: ...312 SVAN 979 User Manual Appendixes Summary curve ...
Страница 348: ...348 SVAN 979 User Manual Appendixes 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz ...
Страница 349: ...349 SVAN 979 User Manual Appendixes 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz ...
Страница 350: ...350 SVAN 979 User Manual Appendixes 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz ...
Страница 351: ...351 SVAN 979 User Manual Appendixes 5600 Hz 6300 Hz 7100 Hz 8000 Hz 8500 Hz 9000 Hz ...
Страница 352: ...352 SVAN 979 User Manual Appendixes 9500 Hz 10000 Hz 10600 Hz 11200 Hz 11800 Hz 12500 Hz ...
Страница 370: ...370 SVAN 979 User Manual Appendixes O ring gasket locations inside ...