5
Maintenance
Rhino
TM
43/54
The manufacturer must be consulted to determine the repairability of cracks in ROPS/
FOPS structures.
HORN/BACk-UP
This roller is equipped with a back-up alarm. Alarm must sound when backing up. It is
the driver’s responsibility to operate this vehicle safely. Be sure back-up alarm and horn
are working.
Inspect the sound decibel level of the horn and back-up alarm daily and test weekly for
proper dBA level (112 dBA). Test results should be recorded in the vehicle’s maintenance
file. If mud, dirt or other debris is forced into alarm, clean and test to ensure proper
operation.
Back-Up Alarm Switch
1. Remove control panel wrap.
2. To check for proper switch operation, connect ohmmeter leads to the wire con-
nections. The back-up switch should be normally open in the neutral position
and normally closed when shifted into reverse position. With the ignition key
in the on position, shifting into reverse should actuate the back-up alarm.
3. Check the assembly for proper switch actuation, smooth lever operation and all
hardware for tightness, then assemble the panel wrap and hardware.