Maintenance
Rhino
TM
43/54
FUEl TANk
Flush and clean the fuel tank annually.
FUEl lINES
Inspect fuel line condition and clamps weekly. Replace fuel lines every 2 years.
BlEEDING AIR FROM FUEl SYSTEM
If your skin comes into contact with high-pressure fuel, ob-
tain medical assistance immediately.
Air will normally be removed from the fuel pump automatically when the engine is in
operation. Bleed air from the fuel system: when replacing fuel filter; disconnecting fuel
lines; after fuel tank has been emptied and/or drained; when fuel system leaks during
operation; or before the engine is to be used following storage.
Escaping fluid under pressure can penetrate the skin causing serious in-
jury. Relieve pressure before disconnecting fuel or other lines. Tighten all
connections before applying pressure. Keep hands and body away from
pinholes and nozzles that eject fluids under high pressure. Use a piece
of cardboard or paper to search for leaks. Do not use your hand.
If any fluid is injected into the skin, a doctor familiar with this type injury
must surgically remove it within a few hours or gangrene may result.
Replace fuel filter every 600 hours or 12 months.
1. Thoroughly clean fuel filter assembly and surrounding area.
2. Loosen drain plug and drain fuel into a suitable container.
NOTE:
Lifting up on retaining ring as it is rotated helps to get it past raised locators.
3. Firmly grasp the retaining ring and rotate it counterclockwise 1/4 turn. Remove
ring with filter element.
4. Inspect filter mounting base for cleanliness. Clean as required.
NOTE:
Raised locators on fuel filter canister must be indexed properly with slots in
mounting base for correct installation.
5. Install new filter element onto mounting. Be sure element is properly indexed
and firmly seated on base. It may be necessary to rotate filter for correct align-
ment.
6. Remove filter element from water separator bowl. Drain and clean separator
bowl. Dry with compressed air. Install water separator bowl onto new element.
Tighten securely.
7. Align keys on filter element with slots in filter base.
8. Install retaining ring onto mounting base making certain dust seal is in place on
filter base. Hand tighten ring (about 1/3 turn) until it “snaps” into the detent.
DO NOT overtighten retaining ring.
WARNING
WARNING
Содержание Rhino 43 Series
Страница 7: ... Stone Construction Equipment Inc 1 Introduction ...
Страница 9: ... Stone Construction Equipment Inc 2 Technical Data ...
Страница 17: ...17 Stone Construction Equipment Inc 3 Health Safety ...
Страница 25: ...25 Stone Construction Equipment Inc 4 Operation ...
Страница 39: ...39 Stone Construction Equipment Inc 5 Maintenance ...