If acid is swallowed:
1. Drink large amounts of water or milk.
2. Then drink milk of magnesia, beaten eggs, or vegetable oil.
3. Get medical attention immediately.
In freezing weather, run engine at lease 30 minutes to assure thorough mixing after add-
ing water to battery.
If necessary to replace battery(ies), replacements must meet or exceed the recommended
capabilities.
BATTERY INSTAllATION
Always connect grounded cable last. Clean and securely connect each cable end to bat-
tery terminal of same polarity. Battery should be securely fastened with properly in-
stalled hold-downs.
CHARGING / JUMPING BATTERY
A 12-volt booster battery can be connected in parallel with battery(ies) on the unit to
aid in cold weather starting. ALWAYS use heavy-duty jumper cables.
Gas given off by battery is explosive. Keep sparks and flames away from bat-
tery. Before connecting or disconnecting a battery charger turn charger
off. Make last connection and first disconnection at a point away from bat-
tery. Always connect negative (-) cable last and disconnect this cable first.
IMPORTANT: Be sure polarity is correct before making connections. Reversed po-
larity will damage electrical system. Always connect positive to positive and nega-
tive to ground. Always use 12-volt booster battery for 12-volt electrical systems.
1. Connect booster battery or batteries to produce the required system voltage for
your engine application.
NOTE:
To avoid sparks, DO NOT allow the free ends of jumper cables to touch the engine.
2. Connect one end of jumper cable to the POSITIVE (+) post of the booster battery.
3. Connect one end of jumper cable to the POSITIVE (+) post of the battery con-
nected to starter.
4. Connect one end of the other jumper cable to the NEGATIVE (-) post of the
booster battery.
5. ALWAYS complete the hook-up by making the last connection of the NEGATIVE
(-) cable to a good ground on the engine frame and away from the battery(ies).
6. Start the engine. Disconnect jumper cables immediately after engine starts.
Disconnect NEGATIVE (-) cable first.
WARNING
Содержание Rhino 43 Series
Страница 7: ... Stone Construction Equipment Inc 1 Introduction ...
Страница 9: ... Stone Construction Equipment Inc 2 Technical Data ...
Страница 17: ...17 Stone Construction Equipment Inc 3 Health Safety ...
Страница 25: ...25 Stone Construction Equipment Inc 4 Operation ...
Страница 39: ...39 Stone Construction Equipment Inc 5 Maintenance ...