Maintenance
Rhino
TM
43/54
ADDING COOlANT
CAUTION:
Explosive release of fluids from pressurized cooling system can cause serious
burns. Shut off engine. Only remove filler cap when cool enough to touch with bare
hands. Slowly loosen cap to first stop to relieve pressure before removing completely.
IMPORTANT
: Never pour cold liquid into a hot engine, as it may crack cylinder
head or block. DO NOT operate engine without coolant for even a few minutes.
Air must be expelled from cooling system when coolant is added.
1. Loosen temperature sending unit fitting at rear of cylinder head to allow air to
escape when filling system.
IMPORTANT: When adding coolant to the system, use the appropriate cool-
ant solution. Coolant 50/50 mixture of antifreeze/distilled water meeting
ASTM 4985, ASTM D5345 (pre-diluted coolant). 50/50 mixture provides pro-
tection to -34° F (-37° C). Do not overfill cooling system. A pressurized sys-
tem needs space for heat expansion without overflowing at top of radiato
r.
2. Fill until coolant level touches bottom of radiator filler neck.
3. Tighten fitting when air has been expelled from system.
DISPOSING OF COOlANT
Improperly disposing of engine coolant can threaten the
environment and ecology.
Use leakproof containers when draining fluids. Do not
use food or beverage containers that may mislead some-
one into drinking from them.
Do not pour waste onto the ground, down a drain, or into
any water source.
Inquire on the proper way to recycle or dispose of waste
from your local environmental or recycling center or from
your dealer.
AIR ClEANER
IMPORTANT: Do not operate engine without the dust unloader valve.
For daily inspection refer to the Operating section of this manual.
Clean the primary (outer) filter element every 250 hours.
IMPORTANT: Always replace secondary safety (inner) filter elements. DO NOT attempt to
clean them. Do not blow air from outside portion of filter with air nozzle. Wear safety
glasses and remove bystanders.
1. Remove air cleaner cover.
2. Remove primary (outer) element only.
3. Thoroughly clean all dirt from inside filter housing.
4. Air cleaner has rubber dust unloader valve on the air cleaner. Squeeze valve tip
to release any trapped dirt particles.
Содержание Rhino 43 Series
Страница 7: ... Stone Construction Equipment Inc 1 Introduction ...
Страница 9: ... Stone Construction Equipment Inc 2 Technical Data ...
Страница 17: ...17 Stone Construction Equipment Inc 3 Health Safety ...
Страница 25: ...25 Stone Construction Equipment Inc 4 Operation ...
Страница 39: ...39 Stone Construction Equipment Inc 5 Maintenance ...