4-2
Operating the Converter
590+ Series DC Digital Converter
Control Philosophy
There are four ways to control the Converter using Remote and Local control:
Start/Stop and Speed Control
There are two forms of control in operation at any time:
Start/Stop
and
Speed Control
. Each can
be individually selected to be under either Local or Remote Control.
x
Local or Remote Start/Stop
decides how you will start and stop the Converter.
x
Local or Remote Speed Control
determines how you will control the motor speed.
In each case, Local and Remote control are offered by using the following:
Local:
The Operator Station
Remote:
Analog and digital inputs and outputs, System Port P3 or the Technology Option
Thus the Converter can operate in two modes:
Note:
Start/Stop is also known as “Sequencing”.
Speed Control is also known as “Reference Generation”.
analog
and digital
inputs and
outputs
PC running
ConfigEd Lite
or other suitable
software
Technology
REMOTE CONTROL
590+ converter
using
590+ converter
using
590+ converter
using
LOCAL CONTROL
590+ converter
using
Option
to fieldbus,
LINK II network,
Comms link
Operator
Station
DEFAULT
Figure 4-1 Remote and Local Control Modes
REMOTE START/STOP
REMOTE
LOCAL START/STOP
LOCAL
SPEED CONTROL
SPEED CONTROL
DEFAULT
SPEED SETPOINT
SPEED SETPOINT
REMOTE CONTROL
LOCAL CONTROL
Figure 4-2 Local and Remote Control