Programming Your Application
6-43
590+ Series DC Digital Converter
INHIBIT ALARMS
Functional Description
19 FIELD FAIL
ENABLED
111 5703 RCV ERROR
ENABLED
28 STALL TRIP INHIBIT
ENABLED
81 SPEED FBK ALARM
ENABLED
92 ENCODER ALARM
ENABLED
305 TRIP RESET
TRUE
FIELD CURRENT
LESS THAN 6% [1]
5703 IN SLAVE MODE
AND COMMS ERROR
FROM CALIBRATION
STALL DELAY
AND STALL THRESHOLD
FROM CALIBRATION
SPDFBK ALM LEVEL
ENCODER FEEDBACK
SELECTED AND ERROR
DETECTED
DRIVE
START
TO ALARM STATUS
FIELD FAIL
5703 RCV ERROR
STALL TRIP
SPEED FBK ALARM
ENCODER ALARM
HEALTH RESET
NOTE [1]:
FIELD FAIL THRESHOLD IS 6% IN CURRENT CONTROL
12% IN VOLTAGE CONTROL
INHIBIT ALARMS
TAG#
PARAMETER
DEFAULT
SETTING
Parameter
Tag
Range
ENCODER ALARM
92
ENABLED / INHIBITED
Inhibits the encoder option board alarm.
REM TRIP INHIBIT
540
ENABLED / INHIBITED
Inhibits the remote trip.
REM TRIP DELAY
541
0.1 to 600.0 SECS
The delay between the remote trip alarm being activated and the drive tripping.