6-14
Programming Your Application
590+ Series DC Digital Converter
CALIBRATION
This function block contains motor-
specific parameters.
When CONFIGURE ENABLE = TRUE,
the operation of the Block Diagram is
suspended and all Operator Station LEDs
will flash.
MMI Menu Map
1
SETUP PARAMETERS
2
CALIBRATION
CONFIGURE ENABLE
NOM MOTOR VOLTS
ARMATURE
CURRENT
FIELD CURRENT
ARMATURE V CAL.
IR COMPENSATION
ENCODER RPM
ENCODER LINES
ANALOG TACH CAL
ZERO SPD. OFFSET
ARMATURE I (A9)
SPDFBK ALM LEVEL
STALL THRESHOLD
STALL TRIP DELAY
REM TRIP DELAY
OVERSPEED LEVEL
FIELD I CAL.
Calibration
TERMINAL VOLTS [ 57]
–
0.00%
TACH INPUT (B2) [ 58]
–
0.0%
ENCODER [ 59]
–
0 RPM
BACK EMF [ 60]
–
0.00%
FIELD FBK. [181]
–
0.0%
1.0000
–
[ 20] ARMATURE V CAL.
0.00 %
–
[ 21] IR COMPENSATION
1.0000
–
[ 23] ANALOG TACH CAL
0.00 %
–
[ 10] ZERO SPD. OFFSET
BIPOLAR
–
[ 25] ARMATURE I (A9)
50.0 %
–
[180] SPDFBK ALM LEVEL
95.00 %
–
[263] STALL THRESHOLD
480.0 s
–
[224] STALL TRIP DELAY
125.00 %
–
[188] OVERSPEED LEVEL
1.0000
–
[182] FIELD I CAL
0x0000
–
[267] POSITION COUNT
1
–
[275] POSITION DIVIDER
Parameter
Tag
Range
TERMINAL VOLTS
57
xxx.xx % (h)
Refer to the DIAGNOSTICS function block description, page 6-23.
TACH INPUT (B2)
58
xxx.xx % (h)
(RAW TACH INPUT)
Refer to the DIAGNOSTICS function block description, page 6-23.
ENCODER
59
xxxxx RPM
(RAW ENCODER RPM)
Refer to the DIAGNOSTICS function block description, page 6-23.
BACK EMF
60
xxx.xx % (h)
Refer to the DIAGNOSTICS function block description, page 6-23.
FIELD FBK.
181
xxx.xx %
(RAW FIELD FBK)
Refer to the DIAGNOSTICS function block description, page 6-23.
ARMATURE V CAL.
20
0.9800 to 1.1000
Trim adjustment of the motor armature volts to give exactly 100% at the required actual
voltage value (e.g. 460V etc.).
Note: - Primary voltage calibration is achieved by adjusting the NOM MOTOR VOLTS
parameter (CONFIGURE DRIVE function block).
IR COMPENSATION
21
0.00 to 100.00 %
Compensation for motor IR drop to improve regulation when using armature voltage
feedback as the speed feedback. This is also used in field weakening applications to
improve dynamic response and speed holding stability, refer to “Initial Start-up Routine” in
Chapter 4, Item 16.
ANALOG TACH CAL
23
0.9800 to 1.1000
Trim adjustment of the motor speed to give exactly 100% at the required actual speed value
(e.g. 1500 RPM etc).
Note: Primary tacho calibration is achieved by adjusting SW1 - 3 on
the tacho calibration board.
ZERO SPD. OFFSET
10
-5.00 to 5.00 %
If the speed feedback is not zero when the drive is stationary (possibly due to hardware
offsets etc.) the setting of this parameter to the value of the offset will result in a zero
reading from the speed feedback.
MMI Menu Map
1
CONFIGURE DRIVE
CONFIGURE ENABLE
NOM MOTOR VOLTS
ARMATURE
CURRENT
FIELD CURRENT
ENCODER LINES
ENCODER RPM