Parameter Specification Table
10-1
590+ Series DC Digital Converter
1
0
P
ARAMETER
T
ABLES
The headings for the Tag No. table are described below.
Tag
A numeric identification of the parameter. It is used to identify the
source and destinations of internal links.
Name
The parameter name as it appears on the MMI.
MMI Menu
The menu page under which the parameter is stored on the MMI.
CE Block
The Function Block under which the parameter is stored in the
ConfigEd Lite programming software.
Range
This varies with parameter type:
INT The upper and lower limits of the parameter, indicating the
parameter’s true, internally-held, number of decimal.
Note:
Decimal Places - some internally held parameters
with two decimal places are only displayed with one
decimal place. These parameters are indicated in
the Parameter Description tables. The Range
parameter highlights these with “(h)”.
BOOL 0 = FALSE, 1 = TRUE
WORD 0x0000 to 0xFFFF (hexadecimal)
Mn
Serial Communications Mnemonic:
Refer to Chapter 14: “Serial Communications”
Notes
Output parameters are not saved in non-vol memory unless noted
otherwise.
Input parameters are saved in non-vol memory unless noted otherwise.
Note 1.
This input parameter is not saved in non-volatile memory.
Note 2.
This input parameter can only be written to when the drive is
stopped.
Note 3.
This input parameter can only be written to when the drive is in
configuration mode.
Note 4.
This parameter is reserved
Parameter Types:
Parameters that look like 0x0000 are WORDS
Parameters that have text are BOOLs if they have a range of 0,1
Parameters that have text are WORDS if their range is 0 to greater than 1
All other parameters are INT (integers)