Programming Your Application
6-9
590+ Series DC Digital Converter
AUX I/O
Parameter
Tag
Range
AUX DIGOUT 1
94
OFF / ON
Software digital output 1. For example, to directly drive the configurable digital output
DIGOUT1, connect the Source of DIGOUT1 to this parameter, Tag 94.
AUX DIGOUT 2
95
OFF / ON
Software digital output 2. For example, to directly drive the configurable digital output
DIGOUT2, connect the Source of DIGOUT2 to this parameter, Tag 95.
AUX DIGOUT 3
96
OFF / ON
Software digital output 3. For example, to directly drive the configurable digital output
DIGOUT3, connect the Source of DIGOUT3 to this parameter, Tag 96.
ANOUT 1
128
-100.00 to 100.00 %
Software analog output 1. For example, to directly drive the configurable analog output
ANOUT1, connect the Source of ANOUT1 to this parameter, Tag 128.
ANOUT 1 can also be used as a general "staging post" for connecting inputs to outputs.
For example, connect Analog Input 1 (A2) directly to Analog Output 1 (A7)
ANOUT 2
129
-100.00 to 100.00 %
Software analog output 2. For example, to directly drive the configurable analog output
ANOUT2, connect the Source of ANOUT2 to this parameter, Tag 129.
ANOUT 2 can also be used as a general "staging post" for connecting inputs to outputs.
For example, connect Analog Input 1 (A2) directly to Analog Output 2 (A8)
JOG/SLACK
496
OFF / ON
Main jog input which is connected to DIGITAL INPUT C4 by default. The Jog input is
ANDed with Auxiliary Jog input , Tag 227, to generate Drive Jog.
ENABLE CURRENT
497
OFF / ON
(ENABLE)
Enable input which is connected to DIGITAL INPUT C5 by default. The Enable input is
ANDed with Auxiliary Enable input , Tag 168, to generate Drive Enable.
REM. SEQ. ENABLE
535
FALSE / TRUE
(REM.SEQ.ENABLE)
(Refer to “Remote Sequencing” below). When enabled, the drive will accept Sequencing
commands exclusively from the REM. SEQUENCE parameter, Tag 536.
FALSE - disables REM. SEQUENCE
TRUE - enables REM. SEQUENCE