Serial Communications
14-1
590+ Series DC Digital Converter
1
4
S
ERIAL
C
OMMUNICATIONS
Communications Technology Option
The plug-in COMMS Option Technology Box provides a serial data port, allowing Converters
to be linked together to form a network. Using a PLC/SCADA or other intelligent device, this
network can be continuously controlled to provide supervision and monitoring for each
Converter in the system. Refer to the Communications Interface Technical Manual for further
details.
Config Ed Lite
This is SSD Drive’s Windows-based block programming software. It has a graphical user-
interface and drawing tools to allow you to create block programming diagrams quickly and
easily. Contact your local SSD Drives sales office.
System Port (P3)
This port has several uses:
1.
ConfigEd Lite
: Parameters can be monitored and updated by ConfigEd Lite (or other
suitable PC programming tool)
2.
UDP Support
: It can be used to upload and download information to a PC
3.
5703 Support
: An SSD Drives' 5703 Setpoint Repeater Unit can be connected
The port is an un-isolated RS232, 9600 Baud (default), supporting the standard EI BISYNCH
ASCII communications protocol, contact SSD Drives for further information.
A standard P3 lead is used to connect to the Converter.
P3 Port Pin
Lead
Signal
1
Black
0V
2
Red
24V
3
Green
TX
4
Yellow
RX
6-Way Lead to DB9/DB25 Connector
Note:
There is 24V present on pin 2 of the P3 port. This may damage your PC or the Converter.
P3 Port Pin
Lead
Female DB9 Pin
Female DB25 Pin
1
Black
5
7
2
Red
not connected
not connected
3
Green
2
3
4
Yellow
3
2
UDP Support
The P3 port can be used to transfer an ASCII representation of the converter's settings between
the Converter and a host computer.
The transfer uses a simple ASCII file structure and XON / XOFF protocol. This is provided by
most communications packages. Host computers tested include IBM PCs XT/AT, running both
Windows and MSDOS, Psion Organiser 3 and many more.
Transferring data from the Converter to a host computer is defined as “Downloading” ,whereas
transferring data from a host computer to the Converter is defined as “Uploading”.
Refer to Chapter 6: “Programming Your Application” - SYSTEM PORT P3 for parameter
details.