10-18
Parameter Specification Table
590+ Series DC Digital Converter
Tag
Name
MMI Menu
CE Block
Range
MN
Notes
582 AUTO RESET
SETUP PARAMETERS::SRAMP
Same as Tag 43
q6
583 EXTERNAL RESET
SETUP PARAMETERS::SRAMP
Same as Tag 43
q7
584 RESET VALUE
SETUP PARAMETERS::SRAMP
-100.00 to 100.00 %
q8
585 QUENCH
SETUP PARAMETERS::SRAMP
Same as Tag 43
q9
586 AT SPEED LEVEL
SETUP PARAMETERS::SRAMP
0.00 to 100.00 %
qa
587 AT SPEED
SETUP PARAMETERS::SRAMP
qb
Output
588 ACCEL OUTPUT
SETUP PARAMETERS::SRAMP
qc
Output
589 SRAMP OUTPUT
SETUP PARAMETERS::SRAMP
qd
Output
590 SRAMP DEST
SYSTEM::CONFIGURE I/O::BLOCK
DIAGRAM
0 to 639
qe
2,3
591 OVERSHOOT THRESH SETUP PARAMETERS::SRAMP
-100.00 to 100.00 %
qf
4
592 ERROR THRESH
SETUP PARAMETERS::SRAMP
-100.00 to 100.00 %
qg
4
593 OUTPUT FPM
SETUP PARAMETERS::PRESET SPEEDS
qh
Output
594 CURR DECAY RATE
SETUP PARAMETERS::STOP RATES
0.00 to 200.00
qi
595 PRESET TORQUE
SETUP PARAMETERS::SPEED LOOP
-200.00 to 200.00 %
qj
596 DECEL JERK 1
SETUP PARAMETERS::SRAMP::RATE SET
0
0.00 to 100.00 %
qk
597 DECEL JERK 1
SETUP PARAMETERS::SRAMP::RATE SET
1
0.00 to 100.00 %
ql
600 LIMIT
SETUP PARAMETERS::PRESET SPEEDS
Same as Tag 43
qo
601 DELTA
SETUP PARAMETERS::SPEED
LOOP::ADVANCED::INERTIA COMP
qp
Output
602 INERTIA COMP O/P
SETUP PARAMETERS::SPEED
LOOP::ADVANCED::INERTIA COMP
Output
603 UNSCALED OUTPUT
SETUP PARAMETERS::SPEED
LOOP::ADVANCED::INERTIA COMP
qr
Output
604 PRESET T SCALE
SETUP PARAMETERS::SPEED LOOP
-200.00 to 200.00 %
qs
605 ARM VOLTS FBK
DIAGNOSTICS
qt
Output
610 GRAY SCALE
SETUP PARAMETERS::PRESET SPEEDS
Same as Tag 43
qy
611 ACCEL JERK 2
SETUP PARAMETERS::SRAMP::RATE SET
0
0.00 to 100.00 %
qz
612 ACCEL JERK 2
SETUP PARAMETERS::SRAMP::RATE SET
1
0.00 to 100.00 %
r0
613 DECEL JERK 2
SETUP PARAMETERS::SRAMP::RATE SET
0
0.00 to 100.00 %
r1
614 DECEL JERK 2
SETUP PARAMETERS::SRAMP::RATE SET
1
0.00 to 100.00 %
r2
617 FIELD I THRESH
SETUP PARAMETERS::FIELD CONTROL
0.00 to 100.00 %
r5
618 UP TO FIELD
SETUP PARAMETERS::FIELD CONTROL
r6
Output
620 INVERT
SETUP PARAMETERS::RAMPS
Same as Tag 43
r8
623 EXTENDED PLL
RESERVED
Same as Tag 43
rb
4