6-90
Programming Your Application
590+ Series DC Digital Converter
TEC OPTION
This function block is used to configure the
inputs and outputs of the various
Technology Options that can be fitted.
The Technology Option provides a
communications interface for external control
of the Converter.
Refer to the appropriate Technology Option
Technical Manual supplied with the option for
further details.
Tec Option
FAULT
[506]
–
NONE
VERSION
[507]
–
0x0000
OUTPUT 1
[508]
–
0x0000
OUTPUT 2
[509]
–
0x0000
NONE
–
[500] TYPE
0
–
[501] INPUT 1
0
–
[502] INPUT 2
0
–
[503] INPUT 3
0
–
[504] INPUT 4
0
–
[505] INPUT 5
MMI Menu Map
1
SERIAL LINKS
2
TEC OPTION
TEC OPTION TYPE
TEC OPTION IN 1
TEC OPTION IN 2
TEC OPTION IN 3
TEC OPTION IN 4
TEC OPTION IN 5
TEC OPTION FAULT
TEC OPTION VER
TEC OPTION OUT 1
TEC OPTION OUT 2
Parameter
Tag
Range
FAULT
506
See below
(TEC OPTION FAULT)
The fault state of the Technology Option.
0 : NONE
no faults
1 : PARAMETER
parameter out-of-range
2 : TYPE MISMATCH
TYPE parameter mismatch
3 : SELF TEST
hardware fault - internal
4 : HARDWARE
hardware fault - external
5 : MISSING
no option fitted
6: VERSION NUMBER
older than Version 2.x
If the VERSION NUMBER error message is displayed, the Technology Option is using
software that doesn’t fully support the drive; refer to SSD Drives.
VERSION
507
0x0000 to 0xFFFF
(TEC OPTION VER)
The version of the Technology Option. If no option is fitted then the version is reset to zero.
OUTPUT 1 to OUTPUT 2
508, 509
xxxxx
(TEC OPTION OUT 1 to TEC OPTION OUT 2)
The use of these output parameters depends upon the type of Technology Option fitted. Refer
to the Technology Option Technical Manual.
TYPE
500
See below
(TEC OPTION TYPE)
Selects the type of Technology Option.
0 : NONE
1 : RS485
2 : PROFIBUS
3 : LINK
4 : DEVICE NET
5 : CAN OPEN
6 : LONWORKS
7 : CONTROLNET
8 : MODBUS PLUS
9 : ETHERNET
10 : TYPE 10
11 : TYPE 11
12 : TYPE 12
13 : TYPE 13
14 : TYPE 14
15 : TYPE 15
INPUT 1 to INPUT 5
501, 502, 503, 504, 505
-32768 to 32767
(TEC OPTION IN 1 to TEC OPTION IN 5)
The use of these input parameters depends upon the type of Technology Option fitted. Refer
to the Technology Option Technical Manual.