6-78
Programming Your Application
590+ Series DC Digital Converter
SRAMP
This function block limits the rate of
change of an input by limiting the
acceleration and the jerk (rate of
change of acceleration).
SRamp
OUTPUT
[589]
–
0.00 %
ACCEL OUTPUT
[588]
–
0.00 %
AT SPEED
[587]
–
FALSE
0.00 %
–
[574] INPUT
0
–
[575] RATE SELECT
TRUE
–
[582] AUTO RESET
FALSE
–
[583] EXTERNAL RESET
0.00 %
–
[584] RESET VALUE
FALSE
–
[585] QUENCH
1.00 %
–
[586] AT SPEED LEVEL
5.00 %
–
[591] OVER SHOOT THRESHOLD
0.50 %
–
[592] ERROR THRESHOLD
60.00 %
–
[576] ACCEL 0
60.00 %
–
[577] DECEL 0
20.00 %
–
[578] ACCEL 0 JERK 1
20.00 %
–
[611] ACCEL 0 JERK 2
20.00 %
–
[596] DECEL 0 JERK 1
20.00 %
–
[613] DECEL 0 JERK 2
30.00 %
–
[579] ACCEL 1
30.00 %
–
[580] DECEL 1
20.00 %
–
[581] ACCEL 1 JERK 1
20.00 %
–
[612] ACCEL 1 JERK 2
20.00 %
–
[597] DECEL 1 JERK 1
20.00 %
–
[614] DECEL 1 JERK 2
MMI Menu Map
1
SETUP PARAMETERS
2
SPECIAL BLOCKS
3
SRAMP
INPUT
SRAMP OUTPUT
ACCEL OUTPUT
AT SPEED
AT SPEED LEVEL
QUENCH
RESET VALUE
EXTERNAL VALUE
AUTO RESET
RATE SET 1
RATE SET 0
RATE SELECT
MMI Menu Map
1
SETUP PARAMETERS
2
SPECIAL BLOCKS
3
SRAMP
4
RATE SET 1
ACCEL 1
DECEL JERK 2
DECEL JERK 1
ACCEL JERK 2
ACCEL JERK 1
DECEL 1
Parameter
Tag
Range
OUTPUT
589
.xx %
(SRAMP OUTPUT)
Diagnostic, ramp output.
ACCEL OUTPUT
588
.xx %
Accleration diagnostic.
AT SPEED
587
FALSE / TRUE
Diagnostic output indicating the Abs (input - output) is less than AT SPEED LEVEL.
INPUT
574
-100.00 to 100.00 %
Input value.
RATE SELECT
575
0 to 1
Selects between one of two parameter sets. This allows you to have two operating modes
(RATE SET 0 or RATE SET 1) with independent ramp parameters.
AUTO RESET
582
FALSE / TRUE
The ramp is reset automatically when the drive is enabled if set to TRUE.
EXTERNAL RESET
583
FALSE / TRUE
Resets the ramp output.
RESET VALUE
584
-100.00 to 100.00 %
The output value while RESET is TRUE also used as initial value on start up. If this is
linked to speed feedback, the initial ramp output will be set to the current value of speed
feedback.
QUENCH
585
FALSE / TRUE
If TRUE forces the ramp input to zero.
AT SPEED LEVEL
586
0.00 to 100.00 %
Threshold for AT SPEED diagnostic output.
OVER SHOOT
THRESHOLD
591
-100.00 to 100.00 %
(OVERSHOOT THRESH)
Reserved parameter for use by SSD Drives.
ERROR THRESHOLD
592
-100.00 to 100.00 %
Hysterisis level before s-ramp operates.
Reserved parameter for use by SSD Drives.
MMI Menu Map
1
SETUP PARAMETERS
2
SPECIAL BLOCKS
3
SRAMP
4
RATE SET 0
ACCEL 0
DECEL JERK 2
DECEL JERK 1
ACCEL JERK 2
ACCEL JERK 1
DECEL 0