6-44
Programming Your Application
590+ Series DC Digital Converter
INTERNAL LINKS
Use internal links to connect an internal input to an internal output, and to connect an
input terminal to multiple destinations.
None of the links are connected in the default configuration.
LINKS 1 to 10
Each link has a SOURCE TAG and DESTINATION TAG parameter. The default value for all
parameters is 0 (zero).
Link 12
OUTPUT DEST [396]
–
0
0
–
[395] INPUT SOURCE
0
–
[399] AUX INPUT SOURCE
OFF
–
[397] ADVANCED
SWITCH
–
[398] MODE
MMI Menu Map
1
SYSTEM
2
CONFIGURE I/O
3
INTERNAL LINKS
4
LINK 11
4
LINK 12
SOURCE TAG
DESTINATION TAG
ADVANCED
MODE
AUX. SOURCE
Link 11
OUTPUT DEST [391]
–
0
0
–
[390] INPUT SOURCE
0
–
[394] AUX INPUT SOURCE
OFF
–
[392] ADVANCED
SWITCH
–
[393] MODE
Parameter
Tag
Range
LINK 1
OUTPUT DEST
365
0 to 639
(DESTINATION TAG)
Enter the tag number for the destination output value.
Refer to “Special Links”, page 6-1.
INPUT SOURCE
364
0 to 639
(SOURCE TAG)
Enter the tag number of the source input value.
Refer to “Special Links”, page 6-1.
LINK 2
OUTPUT DEST
367
0 to 639
INPUT SOURCE
366
0 to 639
LINK 3
OUTPUT DEST
369
0 to 639
INPUT SOURCE
368
0 to 639
LINK 4
OUTPUT DEST
371
0 to 639
INPUT SOURCE
370
0 to 639
LINK 5
OUTPUT DEST
455
0 to 639
INPUT SOURCE
454
0 to 639
LINK 6
OUTPUT DEST
457
0 to 639
INPUT SOURCE
456
0 to 639
LINK 7
OUTPUT DEST
459
0 to 639
INPUT SOURCE
458
0 to 639
LINK 8
OUTPUT DEST
461
0 to 639
INPUT SOURCE
460
0 to 639
LINK 9
OUTPUT DEST
468
0 to 639
INPUT SOURCE
467
0 to 639
LINK 10
OUTPUT DEST
470
0 to 639
INPUT SOURCE
469
0 to 639