The Default Application
15-3
590+ Series DC Digital Converter
0.00 %
0.00 %
Speed Loop
–
OUTPUT
[356]
–
0.00 %
–
SPEED FEEDBACK
[ 62]
–
–
SPEED SETPOINT
[ 63]
–
–
SPEED ERROR
[ 64]
–
0.00 %
10.00
–
[ 14] PROP. GAIN
–
0.500 s
–
[ 13] INT. TIME CONST.
–
OFF
–
[202] INT. DEFEAT
–
0.000
–
[547] SPEED FBK FILTER
–
3
–
[554] ENCODER FILTER
–
0.00 %
–
[289] SETPOINT 1
–
POSITIVE
–
[ 9] SIGN 2 (A3)
–
1.0000
–
[ 7] RATIO 2 (A3)
–
–
SETPOINT 2 (A3)
[290]
–
0.00 %
0.00 %
–
[291] SETPOINT 3
–
0.00 %
–
[ 41] SETPOINT 4
–
105.00 %
–
[357] MAX DEMAND
–
-105.00 %
–
[358] MIN DEMAND
–
0.00 %
–
[595] PRESET TORQUE
–
100.00 %
–
[604] PRESET T SCALE
–
Stop Rates
–
SPEED DEMAND
[ 89]
–
0.00 %
–
PROGRAM STOP
[ 80]
–
FALSE
10.0 s
–
[ 27] STOP TIME
–
60.0 s
–
[217] STOP LIMIT
–
1.0 s
–
[302] CONTACTOR DELAY
–
0.0
–
[594] CURR DECAY RATE
–
0.1 s
–
[ 26] PROG STOP TIME
–
60.0 s
–
[216] PROG STOP LIMIT
–
100.00 %
–
[ 91] PROG STOP I LIM
–
2.00 %
–
[ 29] STOP ZERO SPEED
–
Current Loop
–
AT CURRENT LIMIT [ 42]
–
FALSE
–
IA DEMAND [66]
–
0.00%
–
IA FEEDBACK [65]
–
0.00%
–
IA FEEDBACK [538]
–
0.0 AMPS
–
IF FEEDBACK [539]
–
0.0 AMPS
–
AUTOTUNE [ 18]
–
OFF
–
ILOOP SUSPEND [ 46]
–
FALSE
–
MASTER BRIDGE [527]
–
OFF
100.00 %
–
[ 15] CUR. LIMIT/SCALER
–
110.00 %
–
[421] MAIN CURR. LIMIT
–
45.00 %
–
[ 16] PROP GAIN
–
3.50 %
–
[ 17] INT. GAIN
–
2.00
–
[136] FEED FORWARD
–
12.00 %
–
[137] DISCONTINUOUS
–
0.00 %
–
[ 30] ADDITIONAL DEM
–
DISABLED
–
[ 90] BIPOLAR CLAMPS
–
ENABLED
–
[201] REGEN MODE
–
100.00 %
–
[301] POS. I CLAMP
–
-100.00 %
–
[ 48] NEG. I CLAMP
–
DISABLED
–
[119] I DMD. ISOLATE
–
Analog Ouput 1
62
–
[251] INPUT
–
100.00 %
–
[245] 10V CAL
–
0.00 %
–
[464] OFFSET
–
FALSE
–
[362] MODULUS
–
–
ANOUT 1 (A7) [ 55]
–
0.00 V
Analog Output 2
63
–
[252] INPUT
–
100.00%
–
[248] 10V CAL
–
0.00%
–
[465] OFFSET
–
FALSE
–
[363] MODULUS
–
–
ANOUT 2 (A8) [ 56]
–
0.00 V
CURRENT PROFILE
100.0 %
–
[ 32] SPD BRK 1 (LOW)
–
100.0 %
–
[ 31] SPD BRK 2 (HIGH)
–
200.0 %
–
[ 93] IMAX BRK 1 (SPD1)
–
200.0 %
–
[ 33] IMAX BRK 2 (SPD2)
–
Digital Input 1
–
OUTPUT [102]
–
90
0.01 %
–
[103] VALUE TRUE
–
0.00 %
–
[104] VALUE FALSE
–
–
DIGIN 1 (C6) [ 71]
–
OFF
Digital Input 2
–
OUTPUT [105]
–
118
0.01 %
–
[106] VALUE TRUE
–
0.00 %
–
[107] VALUE FALSE
–
–
DIGIN 2 (C7) [ 72]
–
OFF
Digital Input 3
–
OUTPUT [108]
–
119
0.01 %
–
[109] VALUE TRUE
–
0.00 %
–
[110] VALUE FALSE
–
–
DIGIN 3 (C8) [ 73]
–
OFF
DIGOUT 1 (B5)
77
–
[ 97] INPUT
–
FALSE
–
[359] INVERTED
–
0.00 %
–
[195] THRESHOLD
–
TRUE
–
[ 43] MODULUS
–
–
DIGOUT 1 (B5) [ 74]
–
OFF
DIGOUT 2 (B6)
122
–
[ 98] INPUT
–
FALSE
–
[360] INVERTED
–
0.00 %
–
[196] THRESHOLD
–
TRUE
–
[ 44] MODULUS
–
–
DIGOUT 2 (B6) [ 75]
–
OFF
DIGOUT 3 (B7)
125
–
[ 99] INPUT
–
FALSE
–
[361] INVERTED
–
0.00 %
–
[197] THRESHOLD
–
TRUE
–
[ 45] MODULUS
–
–
DIGOUT 3 (B7) [ 76]
–
OFF
Field Control
–
FIELD ENABLED [169]
–
DISABLED
–
FIELD DEMAND
[183]
–
0.00%
–
FLD. FIRING ANGLE
[184]
–
0.00 DEG
ENABLED
–
[170] FIELD ENABLE
–
VOLTAGE
–
[209] FLD CTRL MODE IS
–
90.00%
–
[210] RATIO OUT/IN
–
100.00%
–
[171] SETPOINT
–
0.10
–
[173] PROP. GAIN
–
1.28
–
[172] INT. GAIN
–
DISABLED
–
[174] FLD. WEAK ENABLE
–
2.00
–
[175] EMF LEAD
–
40.00
–
[176] EMF LAG
–
0.30
–
[177] EMF GAIN
–
10.00%
–
[179] MIN FIELD CURRENT
–
100.00%
–
[178] MAX VOLTS
–
100
–
[191] BEMF FBK LEAD
–
100
–
[192] BEMF FBK LAG
–
0.0 s
–
[185] FLD. QUENCH DELAY
–
QUENCH
–
[186] FLD. QUENCH MODE
–
Alarms
–
READY [125]
–
FALSE
–
HEALTHY [122]
–
TRUE
–
HEALTH WORD [115]
–
0x0000
–
HEALTH STORE [116]
–
0x0000
–
REMOTE TRIP [542]
–
FALSE
–
STALL TRIP [112]
–
OK
–
LAST ALARM [528]
–
0x0000
ENABLED
–
[ 19] FIELD FAIL
–
ENABLED
–
[111] 5703 RCV ERROR
–
ENABLED
–
[ 28] STALL TRIP INHIBIT
–
TRUE
–
[305] TRIP RESET
–
ENABLED
–
[ 81] SPEED FBK ALARM
–
ENABLED
–
[ 92] ENCODER ALARM
–
ENABLED
–
[540] REM TRIP INHIBIT
–
10.0 SECS
–
[541] REM TRIP DELAY
–
Jog/Slack
–
OPERATING MODE [212]
–
STOP
5.00 %
–
[218] JOG SPEED 1
–
-5.00 %
–
[219] JOG SPEED 2
–
5.00 %
–
[253] TAKE UP 1
–
-5.00 %
–
[254] TAKE UP 2
–
10.00 %
–
[225] CRAWL SPEED
–
FALSE
–
[228] MODE
–
1.0 SECS
–
[355] RAMP RATE
–
Raise/Lower
–
OUTPUT [264]
–
0.00%
0.00 %
–
[255] RESET VALUE
–
10.0 s
–
[256] INCREASE RATE
–
10.0 s
–
[257] DECREASE RATE
–
FALSE
–
[261] RAISE INPUT
–
FALSE
–
[262] LOWER INPUT
–
-100.00 %
–
[258] MIN VALUE
–
100.00 %
–
[259] MAX VALUE
–
FALSE
–
[307] EXTERNAL RESET
–
Setpoint Sum 1
–
SPT. SUM [ 86]
–
0.00%
1.0000
–
[ 6] RATIO 1
–
1.0000
–
[208] RATIO 0
–
POSITIVE
–
[ 8] SIGN 1
–
POSITIVE
–
[292] SIGN 0
–
1.0000
–
[419] DIVIDER 1
–
1.0000
–
[420] DIVIDER 0
–
0.00 %
–
[131] DEADBAND
–
105.00 %
–
[375] LIMIT
–
0.00 %
–
[423] INPUT 2
–
0.00 %
–
[100] INPUT 1
–
0.00 %
–
[309] INPUT 0
–
Standstill
–
AT ZERO SETPOINT [ 78]
–
FALSE
–
AT ZERO SPEED [ 77]
–
FALSE
–
AT STANDSTILL [ 79]
–
FALSE
89
–
[306] ZERO SETPOINT
–
DISABLED
–
[ 11] STANDSTILL LOGIC
–
2.00%
–
[ 12] ZERO THRESHOLD
–
5703
–
SCALED INPUT [189]
–
0.00%
–
RAW INPUT [187]
– 0.00%
89
–
[134] OUTPUT
–
0.0000
–
[132] SETPT. RATIO
–
POSITIVE
–
[133] SETPT. SIGN
–
Analog Input 1
–
OUTPUT [246]
–
100
1.0000
–
[230] CALIBRATION
–
100.00 %
–
[231] MAX VALUE
–
-100.00 %
–
[232] MIN VALUE
–
–
ANIN 1 (A2) [ 50]
–
0.00V
-100.00 %
Analog Input 3
–
OUTPUT [249]
–
5
1.0000
–
[236] CALIBRATION
–
100.00 %
–
[237] MAX VALUE
–
–
[238] MIN VALUE
–
–
ANIN 3 (A4) [ 52]
–
0.00V
Analog Input 2
–
OUTPUT [493]
–
0.00%
1.0000
–
[233] CALIBRATION
–
100.00 %
–
[234] MAX VALUE
–
-100.00 %
–
[235] MIN VALUE
–
–
ANIN 2 (A3) [ 51]
–
0.00V
200.00 %
-200.00 %
Analog Input 4
–
OUTPUT [250]
–
48
1.0000
–
[239] CALIBRATION
–
–
[240] MAX VALUE
–
–
[238] MIN VALUE
–
–
ANIN 4 (A5) [ 53]
–
0.00V
Analog Input 5
–
OUTPUT [247]
–
301
1.0000
–
[242] CALIBRATION
–
200.00 %
–
[243] MAX VALUE
–
-200.00 %
–
[244] MIN VALUE
–
–
ANIN 5 (A6) [ 54]
–
0.00V
0.00 %
OFF
0.00 %
Ramps
–
RAMP OUTPUT
[ 85]
–
–
RAMPING
[113]
–
FALSE
10.0 s
–
[ 2] RAMP ACCEL TIME
–
10.0 s
–
[ 3] RAMP DECEL TIME
–
ENABLED
–
[ 4] CONSTANT ACCEL
–
–
[118] RAMP HOLD
–
FALSE
–
[620] INVERT
–
–
[ 5] RAMP INPUT
–
2.50 %
–
[266] % S-RAMP
–
0.50 %
–
[286] RAMPING THRESH.
–
ENABLED
–
[287] AUTO RESET
–
DISABLED
–
[288] EXTERNAL RESET
–
0.00 %
–
[422] RESET VALUE
–
0.00 %
–
[126] MIN. SPEED
–
Aux I/O
–
START (C3)
[ 68]
–
OFF
–
DIGIN (C4)
[ 69]
–
OFF
–
DIGIN (C5)
[ 70]
–
OFF
SEQ STATUS
[537]
–
0x0000
–
REM SEQUENCE
[536]
–
0x0000
ON
–
[161] AUX START
–
ON
–
[227] AUX JOG
–
ON
–
[168] AUX ENABLE
–
OFF
–
[ 94] AUX DIGOUT 1
–
OFF
–
[ 95] AUX DIGOUT 2
–
OFF
–
[ 96] AUX DIGOUT 3
–
0.00 %
–
[128] ANOUT 1
–
0.00 %
–
[129] ANOUT 2
–
OFF
–
[496] JOG/SLACK
–
OFF
–
[497] ENABLE CURRENT
–
FALSE
–
[535] REM. SEQ. ENABLE
–
Configure Drive
100 V
–
[521] NOM MOTOR VOLTS
–
2.0 A
–
[523] ARMATURE CURRENT
–
0.2 A
–
[524] FIELD CURRENT
–
VOLTAGE
–
[209] FIELD CONTROL MODE
–
90.00%
–
[210] FIELD VOLTAGE RATIO
–
ARM VOLTS
–
[ 47] SPEED FBK SEL
–
1000 RPM
–
[ 22] ENCODER RPM
–
1000
–
[ 24] ENCODER LINES
–
POSITIVE
–
[ 49] ENCODER SIGN
–
Calibration
–
TERMINAL VOLTS [ 57]
–
0.00%
–
TACH INPUT (B2) [ 58]
–
0.0%
–
ENCODER [ 59]
–
0 RPM
–
BACK EMF [ 60]
–
0.00%
–
FIELD FBK. [181]
–
0.0%
1.0000
–
[ 20] ARMATURE V CAL.
–
0.00 %
–
[ 21] IR COMPENSATION
–
1.0000
–
[ 23] ANALOG TACH CAL
–
0.00 %
–
[ 10] ZERO SPD. OFFSET
–
BIPOLAR
–
[ 25] ARMATURE I (A9)
–
50.0 %
–
[180] SPDFBK ALM LEVEL
–
95.00 %
–
[263] STALL THRESHOLD
–
480.0 s
–
[224] STALL TRIP DELAY
–
125.00 %
–
[188] OVERSPEED LEVEL
–
1.0000
–
[182] FIELD I CAL
–
0x0000
–
[267] POSITION COUNT
–
1
–
[275] POSITION DIVIDER
–
Programming Block Diagram - Sheet 1