Wire the fault output to any 24VDC buzzer, light or PLC. For wiring to the 1550+ panel, order the parts shown in
the 1550+ manual. You will need the splitter and the extra cable shown below. Kit 040TS04000054W0 includes
both parts.
This end goes in the Main connector on the 1550+ panel. The black and the white wires from the flying leads cable
get wired to your PLC or light or buzzer, snip the blue and brown wires, they are not used. Fault cable pinout
below:
If any electric nozzles are used, they get hooked up to the open M12 connector on the wye connector.