Secondary Run/Enable Trigger or Level Switch Input
The 1550+ controller features an optional secondary run enabled trigger (Trigger Interlock feature) or a
digital input for a level switch.
Note:
Only one can be used at a time.
For the secondary run trigger
, this feature provides a way for you to provide a run signal to the
controller. If this signal is not present, then the system will ignore the trigger signal. An example of this
would be if you do not want the nozzle to spray unless the conveyor is running and there is a part
present to spray.
For the level switch option
, this feature allows you to wire in a NO (Normally Open) level switch from a
liquid tote or tank. When the tank runs low the level switch contacts closes and the 1550+ will send a
24vdc signal to either a customer supplied warning light or to a PLC.
To use these features, you need our cable part number LE00M8F5M.
o
Panel connection: T. int. (Software – DI1+DI2)
o
Cable: 16.4 ft. [5 m] cord length
o
Flying Leads
o
Connector end – M8 4 pin female
Color Code
Pin #
Color
Description
1
Brown
+ 24VDC (not used)
2
White
not used
3
Blue
0 VDC
4
Black
DI1
Содержание 1550+ AutoJet
Страница 35: ...35 Graphic Representation of Fixed Spray Time Using PWM Variable Spray Time...
Страница 74: ...74 Data Sheets Pump Versions...
Страница 75: ...75...
Страница 76: ...76...
Страница 77: ...77 Data Sheets Pump Less Versions...
Страница 78: ...78...
Страница 79: ...79...
Страница 80: ...80 Data Sheets Pressure Pot versions...
Страница 81: ...81...
Страница 82: ...82...
Страница 83: ...83...
Страница 84: ...84 Control Panel Only Version...
Страница 85: ...85 Notes...