![Spraying Systems Co 1550+ AutoJet Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/spraying-systems-co/1550-autojet/1550-autojet_owners-manual_1351346054.webp)
54
o
Cable: 9.8 ft. [3 m] cord length
o
Connector – Mini DIN
o
Connector – M12 3 pin male
Electrical Junction Block
If multiple PulsaJet or AA250 electric spray nozzles are used the system comes complete with a junction block to connect
the spray nozzles to the unit.
The Junction Block is available in two versions: four (4) and eight (8) nozzle connections.
The cable that connects the junction block to the controller will be preassembled. In the event that this becomes
disconnected from the junction block follow the wiring diagram above.
Fault Output Signal
The 1550+ offers a feature to signal your system when a fault has occurred in the operation of the controller. This is wired
as shown in the diagram in Section 15.1. To activate this feature, you need to have our optional splitter cable kit.
o
Panel connection: Main
Pin 1 - Brown - PWM+ (Goes to +)
Pin 3 - Blue - PWM- (Goes to -)