52
Wired normally open
Can be wired normally closed
o
M12 (M) connector – connects to “Main” on control panel - 4 pin
o
16.4 ft (5m) cable length
Optional Input Signal Offering
Optional Input signal offering consists of a cable with connector and flying leads to be connected to the customer's
conditioned 4-20 mA signal in order to remotely control the PWM (Pulse Width Modulation) feature of the 1550+ Spray
Controller. When connected correctly, the Duty Cycle on the controller display adjusts according to the input signal, 4mA
corresponds to 0% PWM and 20 mA corresponds to 100%, when
Duty Cycle
is set to
Remote
.
This will display value when the nozzle is triggered.
Assembly Specifications:
o
Panel connection: 4-20mA
o
Part number: LE00M8M5M
o
Cable: 16.4 ft. [5 m] cord
o
Flying Leads
o
Connector – M8 4 pin male
Color Code
Pin #
Color
Description
1
Brown
+24 VDC
2
White
4-20mA
3
Blue
0 VDC
4
Black
Not used
Duty cycle will display remote input when
connected correctly. Not active or accessible
for local adjustment
Note:
If your 0VDC is coming from a
power supply outside of our panel,
connect it to this wire – Pin #3
Содержание 1550+ AutoJet
Страница 35: ...35 Graphic Representation of Fixed Spray Time Using PWM Variable Spray Time...
Страница 74: ...74 Data Sheets Pump Versions...
Страница 75: ...75...
Страница 76: ...76...
Страница 77: ...77 Data Sheets Pump Less Versions...
Страница 78: ...78...
Страница 79: ...79...
Страница 80: ...80 Data Sheets Pressure Pot versions...
Страница 81: ...81...
Страница 82: ...82...
Страница 83: ...83...
Страница 84: ...84 Control Panel Only Version...
Страница 85: ...85 Notes...