Repeat
Repeat is used to create spray applications of specific time during a variable length spray period. The lengths of the spray
depends on the specific time delays between the rising and falling edge of the trigger input. Spray follows trigger according
to user settings. The system will spray after trigger goes high then stops until next trigger event. So for every trigger, there
are repeated spray events. For this timing mode you enter “
Start Delay
”,
“Interval Off”, “Interval On”,
and “
Stop Delay
”. To
enter your applications delays and intervals touch the time display box, and a new window will open to allow you to enter
your time.
See example.
We’ve entered
Start Delay
of 1 second,
Interval Off
of 2 seconds,
Interval On
of 4 seconds, and a
Spray Delay
of 1 second.
For every trigger, the system would receive the trigger signal from the sensor then wait for 1 second then it will spray for a
4 second interval be off for a 2 second interval, repeat this process until the sensor no longer sees the object then continue
Содержание 1550+ AutoJet
Страница 35: ...35 Graphic Representation of Fixed Spray Time Using PWM Variable Spray Time...
Страница 74: ...74 Data Sheets Pump Versions...
Страница 75: ...75...
Страница 76: ...76...
Страница 77: ...77 Data Sheets Pump Less Versions...
Страница 78: ...78...
Страница 79: ...79...
Страница 80: ...80 Data Sheets Pressure Pot versions...
Страница 81: ...81...
Страница 82: ...82...
Страница 83: ...83...
Страница 84: ...84 Control Panel Only Version...
Страница 85: ...85 Notes...