![Spraying Systems Co 1550+ AutoJet Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/spraying-systems-co/1550-autojet/1550-autojet_owners-manual_1351346057.webp)
57
Assembly Specifications:
o
Panel connection: Main
o
Part Number: LE00M12M5M
o
Cable: 16.4 ft. [5 m] cord length
o
Flying Leads
o
Connector – M12 4 pin male
Color Code
Pin #
Color
Description
1
Brown
PWM +
2
White
* Fault Output
3
Blue
PWM -
4
Black
+24 VDC
Please note if you are using the DI1+DI2 dual trigger option the level sensor option can’t be used because they utilize the
same electrical port on the controller. You may only use one or the other.
Level sensor input – A level switch (any normally open float switch) can be wired to the system so when the tank level drops
below a certain level, a fault will be shown on the HMI.
Fault Output signal max.
30v/1A NPN