![Spraying Systems Co 1550+ AutoJet Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/spraying-systems-co/1550-autojet/1550-autojet_owners-manual_1351346020.webp)
20
o
Connect suitable 3/8” O.D. tubing from the Liquid Out fitting on the pressure pot to the corresponding fitting on the
spray nozzle(s).
o
Tubing supplied if system is purchased with standard pressure pot.
Metric systems use 10 mm O.D. tubing
Mounting Spray Nozzles
Locate and mount the spray nozzles for your spray application. Depending on your application the spray nozzle lines and
connections will vary. It is recommended to run the lines starting from the spray nozzles to the system for easier
adjustment of lengths of the tubing. Note length should be kept to a minimum to reduce pressure drop. Note: If liquid
lines are long (>10ft.or 3m) flowrates and pressures will be affected. This can be worse when viscous fluids are being
pumped.
Notes on Nozzle Location
When locating the system in relation to the nozzles note these typical lengths of connecting items
You may or may not have these items depending on your project and order.
Nozzle hook up kits – Tubing 12 ft. (3.6m)
If your system was ordered with optional nozzle hook up kit the design of the hook up kit allows for 12’ of tubing from the
nozzle to the system for a single nozzle hook up kit. For multiple nozzle hook up kits they are designed to provide 12’
(3.6m) of tubing from each nozzle to the manifold and 12’ (3.6m) of tubing from the manifold to the system.
Electric nozzle cables – 10 ft. (3m) & 16.4 ft. (5m)
All systems design to use electric nozzles comes with the required cables. IF your system did not come with these cables
please contact your local sales engineer.
For a single electric nozzle system, the cable length is 10’ (3m) [Cable P/N LEXXSD3M83F030P, for AA10000 series;
P/N LE00M12MMDIN3MU for AA250 series]. For multiple electrical nozzles the system comes with cable from the
nozzle (one per nozzle) to a junction block that is 10’ (3m) [Cable P/N LEXXSD3M83F030P, for AA10000 series; P/N
LE00M12MMDIN3MU for AA250 series] and a cable from the junction block to the system that is 16.4 ft (5m)
{Cable P/N LE00M12M5M].
If longer length cables are required, we offer an extension cable that is 16.4’ (5m) [Cable P/N LEXXSD4FD4M005P].
o
This cable can be used to go between the nozzle cable and the junction block or the junction block cable
and the system.
o
This cable can also be used to extend the trigger devise cable lengths stated below.
o
Note due to voltage drop we recommend keeping the cable length to a reasonable length (approx. <50ft.).
Never attempt to chain more than four (4) cables together. Electric spray nozzle speed and performance
will suffer.
Trigger device cables – 16.4 ft. (5m)
All systems must be purchased with a trigger device to activate the system during operation. All of our offerings have a
cable length of 16.4’ (5m).
If longer length cables are required we offer an extension cable that is 16.4’ (5m) [Cable P/N LEXXSD4FD4M005P].
o
This cable can be used to go between the trigger cable and the system.
o
This cable can also be used to extend the electric nozzle cable lengths stated above.
Содержание 1550+ AutoJet
Страница 35: ...35 Graphic Representation of Fixed Spray Time Using PWM Variable Spray Time...
Страница 74: ...74 Data Sheets Pump Versions...
Страница 75: ...75...
Страница 76: ...76...
Страница 77: ...77 Data Sheets Pump Less Versions...
Страница 78: ...78...
Страница 79: ...79...
Страница 80: ...80 Data Sheets Pressure Pot versions...
Страница 81: ...81...
Страница 82: ...82...
Страница 83: ...83...
Страница 84: ...84 Control Panel Only Version...
Страница 85: ...85 Notes...