For every trigger, the system would receive the trigger signal from the sensor then wait for 2 seconds then spray for exactly
4 seconds. The system would wait for the next trigger signal and repeat the application.
Spray Delay
is defined as the time the system waits before starting the
Spray Period
.
Spray Delay
time can be set from 0.000 to 9999.999 seconds.
Spray Period
is defined as the time system sprays after the trigger signal and delay time has expired.
Spray Period
time can be set from 0.001 to 9999.999 seconds.
To reiterate in the application the sensor or trigger signal is activated, the spray delay time is activated. Once the
Start
Delay
time is finished the system starts the
Spray Period
time which actuates the spray nozzle then sprays for the set
amount of time.
Note:
The start delay takes precedence over the anticipator time. For example if the anticipator time is set to 2 seconds
and the start delay to 1 sec the spray will still start after a 1 second delay leaving an actual anticipator time of 1 second
Parameters settings for Fixed Spray Time:
Parameter
Value
Start delay
In seconds
Spray period
In seconds. Should be > zero!
Anticipator time
In seconds – for use with air atomizing spray nozzles
Follower time
In seconds – for use with air atomizing spray nozzles
Содержание 1550+ AutoJet
Страница 35: ...35 Graphic Representation of Fixed Spray Time Using PWM Variable Spray Time...
Страница 74: ...74 Data Sheets Pump Versions...
Страница 75: ...75...
Страница 76: ...76...
Страница 77: ...77 Data Sheets Pump Less Versions...
Страница 78: ...78...
Страница 79: ...79...
Страница 80: ...80 Data Sheets Pressure Pot versions...
Страница 81: ...81...
Страница 82: ...82...
Страница 83: ...83...
Страница 84: ...84 Control Panel Only Version...
Страница 85: ...85 Notes...