![Spraying Systems Co 1550+ AutoJet Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/spraying-systems-co/1550-autojet/1550-autojet_owners-manual_1351346047.webp)
47
Trigger Cable Offering
Optional trigger cable offering: Un-terminated flying lead cable and connector.
Required Input:
o
Part Number - LE00M12F5M – M12(f) x bare lead trigger cable
o
NPN – Switch to 0 VDC to turn on spray trigger.
Requires NPN Sensor or dry contact switch.
o
Connects to the connector labeled “Trig.” On the bottom of the panel.
Assembly Specifications:
o
Panel connection: Trig (Software trigger choice - DI2)
o
Cable: 16.4 ft. [5 m] cord length
o
Flying Leads
o
Connector end – M12 4 pin female
Note:
Connect pins 3 & 4 with switch or dry contact to initiate trigger.
WARNING: Never connect pin 1 (24vdc) to any other pin. Doing so could cause equipment damage. (Cut the
brown and white wire if you're not using them)
Color Code
Pin #
Color
Description
1
Brown
+ 24VDC (only used for sensors)
2
White
0 VDC (only used for sensors)
3
Blue
0 VDC
4
Black
DI2
Содержание 1550+ AutoJet