![Spraying Systems Co 1550+ AutoJet Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/spraying-systems-co/1550-autojet/1550-autojet_owners-manual_1351346044.webp)
44
Compressed Air
Inlet Pressure:
100 psi (7 bar) (System designed to work at 100 psi)
Max. Air Flow:
50 SCFM [Accumulated total; including pump, atomizing, and fan air lines]
Required air quality:
Clean, dry air according to DIN ISO 8573-1
Solids - Class 5
Water content – at least class 4 (*) - Cooled down to 59° F below room temperature (location of system)
Oil content – at least class 5
Liquid Data
Liquid Temperature:
32° to 140° F (0° to 60° C)
Viscosity:
<1000 cP
Specific Gravity: <1.5
Operating Liquid Parameters (Spraying water)
Pressure:
Minimum:
5 psi (0.4 bar)
Maximum:
80 psi (5.5 bar) [100 psi (7 bar) maximum capable]
Flow:
Maximum:
2 GPM @ 40 psi (7.6 l/min @ 2.8 bar)
Operating Cylinder Air Parameters
Pressure:
Minimum:
45 psi (5.5 bar)
Maximum:
100 psi (7 bar)
Note: cylinder air pressure will be equal to the inlet air pressure of the system
Operating Atomizing Air Parameters
Pressure:
Minimum:
5 psi (0.4 bar)
Maximum:
60 psi (3.1 bar)
Flow:
Maximum:
40 SCFM @ 40 psi (1130 Nl/min @ 2.8 bar)
Operating Fan Air Parameters
Pressure:
Minimum:
5 psi (0.4 bar)
Maximum:
60 psi (3.1 bar)
Flow:
Maximum:
40 SCFM @ 40 psi (1130 Nl/min @ 2.8 bar)
System Timing - Atomizing Air
Содержание 1550+ AutoJet
Страница 35: ...35 Graphic Representation of Fixed Spray Time Using PWM Variable Spray Time...
Страница 74: ...74 Data Sheets Pump Versions...
Страница 75: ...75...
Страница 76: ...76...
Страница 77: ...77 Data Sheets Pump Less Versions...
Страница 78: ...78...
Страница 79: ...79...
Страница 80: ...80 Data Sheets Pressure Pot versions...
Страница 81: ...81...
Страница 82: ...82...
Страница 83: ...83...
Страница 84: ...84 Control Panel Only Version...
Страница 85: ...85 Notes...