Variable Spray Time is used to create spray applications with variable length. The lengths of the spray depends on the
specific time delays between the rising and falling edge of the trigger input. Spray follows trigger according to user settings.
The system will spray after trigger goes high then stops until next trigger event. So for every trigger, there is a single spray
event. For this timing mode you enter “
Start Delay
” and “
Stop Delay
”. To enter your applications delays touch the time
display box, and a new window will open to allow you to enter your time.
See example.
We’ve entered a
Start Delay
of 2 seconds, and a
Stop Delay
of 1 second.
For every trigger, the system would receive the trigger signal from the sensor then wait for 2 seconds then spray for time
the sensor sees the object the continue to spray for 1 second. The system would wait for the next trigger signal and repeat
the application. The length of time spraying or
Spray Period
varies as the sensor reads the object.
Start Delay
is defined as the time the system waits before starting the
Spray Period
.
Start Delay
time can be set from 0.000 to 9999.999 seconds.
Stop Delay
is defined as the time system sprays after the trigger signal has dropped.
Stop Delay
time can be set from 0.000 to 9999.999 seconds.
To reiterate in the application the sensor or trigger signal is activated, the spray delay time is activated. Once the
Start
Delay
time is finished the system starts the
Spray Period
time which actuates the spray nozzle then sprays for the variable
amount of time based on the sensor reading of the objects, then the system continues to spray for the amount of the
Stop
Delay
has been programmed.
An example of this timing is shown in the following picture.
Parameters settings for Variable Spray Time:
Parameter
Value
Start delay
In seconds
Stop delay
In seconds
Anticipator time
In seconds – for use with air atomizing spray nozzles
Follower time
In seconds – for use with air atomizing spray nozzles
G raphic repres ent ation for V ariable Spray Time Using PWM:
Содержание 1550+ AutoJet
Страница 35: ...35 Graphic Representation of Fixed Spray Time Using PWM Variable Spray Time...
Страница 74: ...74 Data Sheets Pump Versions...
Страница 75: ...75...
Страница 76: ...76...
Страница 77: ...77 Data Sheets Pump Less Versions...
Страница 78: ...78...
Страница 79: ...79...
Страница 80: ...80 Data Sheets Pressure Pot versions...
Страница 81: ...81...
Страница 82: ...82...
Страница 83: ...83...
Страница 84: ...84 Control Panel Only Version...
Страница 85: ...85 Notes...