138
Parameters: < slotno>
is the slot number, or the card located in that slot, the valid range
is 1 to 4, M1, M2, and 5 to 8.
Command mode:
Admin Mode
Usage Guide:
This command can reset all line cards and Standby Master board, but not
the Active Master board.
3.7.5 runcfg-sync
Command: runcfg-sync [<interval>]
Function:
Configure the running-config synchronous interval.
Parameter: <interval>
is the synchronous time interval which is shown in minutes and
ranges between 5~1440 or 0, in which 0 refers to the auto synchronization function is
disabled, no parameter followed refers to enabling running-config synchronizing function.
When the configuration file changes, default synchronization interval is 5 minutes.
Command Mode:
Global mode
Default:
Auto synchronization function disabled by default
Usage Guide:
This command is for configuring the interval between which the active
master synchronizes the running-config to standby master regularly. Undersized interval
configuration will result in unnecessary load to the switch. The auto synchronization
function is recommended to be disable if the configuration is stable or will be saved with
write command after changes take place.
Example:
Set the running-config synchronization interval to 1440 minutes
Switch(Config)#runcfg-sync 1440
3.7.6 show fan
Command: show fan
Function:
Shows whether the fan tray is in place.
Parameters:
N/A.
Default:
No display by default.
Command mode: Admin Mode
Usage Guide:
“YES” for fan in place; “NO” for fan not in place.
Example:
Switch # show fan
----------fan information----------
fan1 board Inserted: YES
fan2 board Inserted: YES
fan3 board Inserted: YES