Modbus
register
Data type /
Size in bytes
Parameter
Description
Default value
[units]
(units register)
Value range /
Setting options
Access
level
10136
Float / 4
Upper range
value current
Upper current value
that is mapped to the
upper nominal range
boundary selected by
Frequency value high
(9235). Applicable if
Process value (9204) =
25 or 26.
20.0
[mA]
-
Read /
write
10138
Float / 4
Lower range
value current
Lower current value
that is mapped to the
lower nominal range
boundary selected by
Frequency value low
(9237). Applicable if
Process value (9204) =
25 or 26.
4.0
[mA]
-
Read /
write
9208
Float / 4
Damping value
Time constant of damp‐
ing filter for frequency
output signal.
0.0
[s]
0.0 - 100.0
Read /
write
9591
Unsigned / 2
Fail-safe activa‐
tion condition
Fail-safe activation con‐
dition.
1
● 0: Bad status of
selected process
value
● 1: Active
Maintenance alarm
or Failure (NAMUR)
Read /
write
9281
Unsigned / 2
Fail-safe min.
time
Minimum time the out‐
put stays in fail-safe be‐
havior.
0
[s]
0 - 100
Read /
write
9239
Unsigned / 2 Fail-safe behav‐
ior
Frequency output reac‐
tion in case of a fault.
2
● 0: Frequency value
low
● 1: Frequency value
high
● 2: Last valid value
● 3: Disabled
● 4: Custom value
Read /
write
9240
Float / 4
Fail-safe value
Output value in case of
a fault and when Fail-
safe behavior (9239) is
configured to 4.
0.0
[Hz]
0.0 - 12500.0
Read /
write
7156
Float / 4
Forced value
Forced value when
forcing is active.
1.0
[Hz]
0.0 - 12500.0
Read /
write
MODBUS commands
4.10 Modbus holding registers tables
FCT030 Modbus (From firmware 4.0)
Function Manual, 06/2018, A5E39931813-AB
99
Содержание SITRANS F Coriolis FCT030
Страница 6: ...Table of contents FCT030 Modbus From firmware 4 0 6 Function Manual 06 2018 A5E39931813 AB ...
Страница 16: ...Communication 2 4 Connecting FCT030 Modbus From firmware 4 0 16 Function Manual 06 2018 A5E39931813 AB ...
Страница 194: ...Definitions A 1 Definitions FCT030 Modbus From firmware 4 0 194 Function Manual 06 2018 A5E39931813 AB ...
Страница 198: ...Index FCT030 Modbus From firmware 4 0 198 Function Manual 06 2018 A5E39931813 AB ...