Modbus
register
Data type /
Size in
bytes
Parameter
Description
Default val‐
ue
[units]
(units
register)
Value range /
Setting options
Access
level
8298
Unsigned /
2
Baud rate
Baud rate of Modbus interface.
19200 Bit/s ● 0: 9600 Bit/s
● 1: 19200 Bit/
s
● 2: 115200
Bit/s
● 3: Reserved
● 4: 38400 Bit/
s
● 5: 57600 Bit/
s
● 6: 76800 Bit/
s
● 7: 1200 Bit/s
● 8: 2400 Bit/s
● 9: 4800 Bit/s
Read /
write
8299
Unsigned /
2
Parity and
framing
Parity and framing of the Modbus
communication interface.
Even pari‐
ty, 1 stop
● 0: Even
parity, 1 stop
● 1: Odd
parity, 1 stop
● 2: No parity,
2 stops
Read /
write