4.10.5.12
Process value filter masks
Process value filter masks
Table 4-58
Process value filter masks
Selected view type
Setting options
Process value filter mask 1
Bit coded mask to specify the process values that are filtered. Bit set
means filtered:
● 0: Mass flow
● 1: Volume flow
● 2: Density
● 3: Medium temperature
● 4: Standard Volume Flow
● 5: Fraction Flow Media A
● 6: Fraction Flow Media B
● 7: Fraction Flow Media A in Percent
● 8: Fraction Flow Media B in Percent
● 9: Reference density
● 10: Transmitter internal temperature
● 11: Totalizer 1
● 12: Totalizer 2
● 13: Totalizer 3
● 17: Sensor frame temperature
4.10.6
Maintenance and diagnostics
Table 4-59
Maintenance & diagnostics
Modbus
register
Data type /
Size in
bytes
Parameter
Description
Default value
[unit]
(unit register)
Value range /
Setting op‐
tions
Access
level
6004
Unsigned /
4
Configuration
counter
Configuration counter.
Counts number of parame‐
ter content modified.
-
-
Read only
MODBUS commands
4.10 Modbus holding registers tables
FCT030 Modbus (From firmware 4.0)
Function Manual, 06/2018, A5E39931813-AB
135
Содержание SITRANS F Coriolis FCT030
Страница 6: ...Table of contents FCT030 Modbus From firmware 4 0 6 Function Manual 06 2018 A5E39931813 AB ...
Страница 16: ...Communication 2 4 Connecting FCT030 Modbus From firmware 4 0 16 Function Manual 06 2018 A5E39931813 AB ...
Страница 194: ...Definitions A 1 Definitions FCT030 Modbus From firmware 4 0 194 Function Manual 06 2018 A5E39931813 AB ...
Страница 198: ...Index FCT030 Modbus From firmware 4 0 198 Function Manual 06 2018 A5E39931813 AB ...