6.6.3
Operation mode ③ - Application macro selection
Application macro selection
. . .
OK
Turn
OK
Turn
OK
Turn
OK
Turn
Figure 6-22 Application macro selection
Application macros available for setting in this mode
A00 to A05
Application macro setting in "Application macro selection" mode
Example: A05
Automatically
Inverter is confirming
the selection
Press
OK
OK
Turn
. . .
Figure 6-23 Application macro setting example
NOTICE
If the inverter is confirming the selection of a connection macro, time consumption is about
50 seconds; if it is confirming the selection of an application macro, the time consumption is
about 20 seconds.
Button/keys inactive in this mode
The STOP, RUN and LOC/REM keys are inactive in this mode.
See also
Application macros (Page 56)
Commissioning
6.6 Overview of various operation modes
SINAMICS V10
Operating Instructions, 08/2011, A5E03453178 (this is not an order number)
69