Order no.:
6SL3217-0CE
Frame Size A
Frame Size B
Frame Size C
Frame Size D
Ambient temperature
Operation
0 °C to 50 °C without power derating (100 % load)
50 °C to 60 °C with power derating
0
20
30
10
40
[
]
50
60
75
50
25
100
[%]
Permissible output current
Operating temperature
C
Inverter derating with increased operating temperature
Transport &
storage
-40 °C to + 70 °C
Relative humidity
5 to 95 %, without condensation
Contamination level
Chemical gases: 3C2 and solid particles: 3S2, according to IEC60721-3-3
Vibration resistance
< 1 G (9.81 m/s
2
) acceleration
Atmospheric pressure
0 to 1, 000 m above sea level: without power derating
1,000 m to 4,000 m: with power derating
6)
80
40
60
20
100
2000 3000 4000
1000
0
2000
460 V
3000 4000
1000
0
%
Installation altitude in m above sea level
Pe
rmi
ssi
b
le
o
u
tp
u
t
cu
rre
n
t
Installation altitude in m above sea level
Pe
rmi
ssi
b
le
i
n
p
u
t
vo
lt
a
g
e
80
77
40
60
20
100
%
Inverter derating with increased altitude
7)
Protection class
IP21 (excluding all input/output terminals)
8)
Standards
CE mark, in accordance with Low-Voltage Directive 2006/95/EC;
1)
Unless otherwise specified, the output current indicated refers to the value that can be reached when the ambient
temperature is at 50 °C.
2)
Can be operated on TNC, TNS, TT or IT, excluding three-phase three-wire systems unearthed or corner-earthed; Can also
be operated on the three-phase three-wire systems unearthed or corner-earthed if an appropriate transformer or a
separately derived source that normally supplies an unearthed system is installed on the mains system.
3)
The digital output terminals are at a dangerously high voltage when Non-SELV control voltage is applied. Use only approved
double insulated cable for supply connection with nominal cross-section area of at least 0.75 mm
2
/ 300 V / 75 °C and
protected by max. 6A external fuse, type gG approved based on IEC 60269.
4)
The depth value in brackets refers to the value of the inverter without the operator panel.
5)
The weight here includes the weight of the operator panel.
Technical data
SINAMICS V10
Operating Instructions, 08/2011, A5E03453178 (this is not an order number)
117