Legend
Meaning
Function
⑧
STOP key
ذℶ
STOP
Press STOP < 2 s: Motor ramp-down (OFF1)
2)
Press STOP > 2 s: Motor to coast to a standstill (OFF2)
3)
⑨
RUN key
运行
RUN
Pressing RUN starts motor.
⑩
OK button
OK
Press OK:
1. Acknowledge fault
2. Loop through motor status data display
3. Confirm the selected connection macro or application
macro
4. Go from a parameter number into its value setting or
into its parameters index no. and back
Turn OK clockwise:
1. Go into the next parameter no., connection macro or
application macro.
2. Accelerate the motor
3. Increase the setpoint
Turn OK
counterclockwise:
1. Go into the last parameter no., connection macro or
application macro.
2. Decelerate the motor
3. Decrease the setpoint
1)
The factory default control mode is "LOC". In most cases, "LOC" is used for debugging purpose only.
2)
For the description of OFF1 function, see "Notes on OFF functions" in Chapter 7.
3)
For the description of OFF2 function, see "Notes on OFF functions" in Chapter 7.
6.3.2
Various data displays
Table 6-14
Various data displays
Display
Example
Meaning
Remarks
-8.8.8.8.8
Inverter display is lighted
-
- - - - -
Inverter initializing
-
busy
Inverter is confirming the selected
connection macro or application
macro, or inverter is busy
-
d xxx
Actual DC-link voltage
-
C xx
Connection macro available for
selection
There are 10 connection macros available for
selection: C01 ... C11.
A xx
Application macro available for
selection
There are 6 application macros available for
selection : A00 ... A05
Commissioning
6.3 Operator panel overview
SINAMICS V10
60
Operating Instructions, 08/2011, A5E03453178 (this is not an order number)