General information
2.7 Technical data
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
65
Parameter
Description
Torque limit
Set through a parameter or the analog input command (0 V DC to +10 V DC/max.
torque)
Position control mode
Max. input pulse frequency
1 M (differential input), 200 kpps (open collector input)
Command pulse multiplying factor Electronic gear ratio (A/B)
A: 1 - 10000, B: 1 - 10000
1/50 <A/B < 200
In-position range setting
0 to ±10000 pulse (command pulse unit)
Error excessive
±1/10 revolutions
Torque limit
Set through a parameter or the analog input command (0 V DC to +10 V DC/max.
torque)
Torque control mode
Analog torque command input
-10 V DC to +10
V DC/max. torque (input impedance 10 kΩ to 12 kΩ)
Speed limit
Set through a parameter or the analog input command (0 V DC to +10 V DC/max.
rated speed)
Environmental conditions
Surrounding air
temperature
Operation
0 °C to 45 °C: without power derating
45 °C to 55 °C: with power derating
Storage
-40 °C to +70 °C
Ambient humidity Operation
< 90% (non-condensing)
Storage
90% (non-condensing)
Operating environment
Indoors (without direct sunlight), free from corrosive gas, combustible gas, oil gas, or
dust
Altitude
≤ 1000 m (without power derating)
Degree of protection
IP 20
Degree of pollution
Class 2
Содержание SIMOTICS S-1FL6
Страница 1: ...SINAMICS V90 SIMOTICS S 1FL6 ...
Страница 2: ......
Страница 87: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 85 ...
Страница 89: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 87 ...
Страница 342: ...Tuning 9 9 PI P switching SINAMICS V90 SIMOTICS S 1FL6 340 Operating Instructions 04 2019 A5E36037884 007 ...
Страница 384: ...Parameters 10 2 Parameter list SINAMICS V90 SIMOTICS S 1FL6 382 Operating Instructions 04 2019 A5E36037884 007 ...
Страница 432: ......