Parameters
10.2 Parameter list
SINAMICS V90, SIMOTICS S-1FL6
354
Operating Instructions, 04/2019, A5E36037884-007
Par. No.
Name
Min
Max
Factory
Setting
Unit Data
type
Effective
Can be
changed
p2574 **
IPos jerk limiting
1
100000000 10000 100
0
LU/s
3
U32
IM
T, U
Description: Sets the jerk limiting.
Dependency: Refer to p2572, p2573, and p2575
Note: The jerk limiting is internally converted into a jerk time as follows:
Jerk time Tr = max(p2572, p2573)/p2574
p2575
IPos jerk limiting activa-
tion
0
1
0
-
U32
IM
T
Description: Activates the jerk limiting.
•
0: The jerk limiting is deactivated.
•
1: The jerk limiting is activated.
Dependency: Refer to p2574
p2580
EPOS software limit
switch minus
-2147482648
214748264
7
-
214748
2648
LU I32
IM
T, U
Description: Sets the software limit switch in the negative direction of travel.
Dependency: Refer to p2581, p2582
p2581
EPOS software limit
switch plus
-2147482648
214748264
7
214748
2647
LU I32
IM
T, U
Description: Sets the software limit switch in the positive direction of travel.
Dependency: Refer to p2580, p2582
p2582
EPOS software limit
switch activation
-
-
0
-
U32/Bina
ry
IM
T
Description: Sets the signal source to activate the "software limit switch".
Dependency: Refer to p2580, p2581
Caution: Software limit switch effective:
- Axis is referenced.
Software limit switch ineffective:
- Modulo correction active.
- Search for reference is executed.
Notice: Target position for relative positioning outside software limit switch:
The traversing block is started and the axis comes to a standstill at the software limit switch. An appropriate
alarm is output and the traversing block is interrupted. Traversing blocks with valid position can be activated.
Target position for absolute positioning outside software limit switch:
In the "traversing blocks" mode, the traversing block is not started and an appropriate fault is output.
Axis outside the valid traversing range:
If the axis is already outside the valid traversing range, then an appropriate fault is output. The fault can be
acknowledged at standstill. Traversing blocks with valid position can be activated.
Note: The traversing range can also be limited using STOP cams.
Содержание SIMOTICS S-1FL6
Страница 1: ...SINAMICS V90 SIMOTICS S 1FL6 ...
Страница 2: ......
Страница 87: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 85 ...
Страница 89: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 87 ...
Страница 342: ...Tuning 9 9 PI P switching SINAMICS V90 SIMOTICS S 1FL6 340 Operating Instructions 04 2019 A5E36037884 007 ...
Страница 384: ...Parameters 10 2 Parameter list SINAMICS V90 SIMOTICS S 1FL6 382 Operating Instructions 04 2019 A5E36037884 007 ...
Страница 432: ......