Connecting
4.3 Control/status interface - X8
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
135
Parameter
Value
Source
p29351
0
Actual speed (reference p29060)
1 (default)
Actual torque (reference 3 × r0333)
2
Speed setpoint (reference p29060)
3
Torque setpoint (reference 3 × r0333)
4
DC bus voltage (reference 1000 V)
5
Pulse input frequency (reference 1 k)
6
Pulse input frequency (reference 10 k)
7
Pulse input frequency (reference 100 k)
8
Pulse input frequency (reference 1000 k)
9
Remaining number of pulses (reference 1 k)
10
Remaining number of pulses (reference 10 k)
11
Remaining number of pulses (reference 100 k)
12
Remaining number of pulses (reference 1000 k)
Wiring
Do wiring of analog outputs as follows: