Benefits of electronic gear (example)
Move the workpiece for 10 mm
Without electronic gear
With electronic gear
Required number of setpoint pulses:
2500 ppr × 4 × (10 mm/6 mm) = 16666
Required number of setpoint pulses:
(10 mm × 1000)/1 LU = 10000
The electronic gear ratio is a multiplier factor to pulse train setpoint. It is realized with a
numerator a
nd a denominator. Four numerators (p29012[0], p29012[1], p29012[2].
p29012[3]) and one denominator (p29013) are used for the four electronic gear ratios.
Parameter
Range
Default
Unit
Description
p29012[0]
1 to 10000
1
-
The first numerator of electronic gear
p29012[1]
1 to 10000
1
-
The second numerator of electronic gear
p29012[2]
1 to 10000
1
-
The third numerator of electronic gear
p29012[3]
1 to 10000
1
-
The forth numerator of electronic gear
p29013
1 to 10000
1
-
The denominator of electronic gear
These four electronic gear ratios can be selected with the combination of the digital input
signals EGEAR1 and EGEAR2 (refer to Section "DIs (Page 123)").
EGEAR2 : EGEAR1
Electronic gear ratio
Ratio value
0 : 0
Electronic gear ratio 1
p29012[0] : p29013
0 : 1
Electronic gear ratio 2
p29012[1] : p29013
1 : 0
Electronic gear ratio 3
p29012[2] : p29013
1 : 1
Electronic gear ratio 4
p29012[3] :
p29013
Note
After a gear ratio is switched to another one via digital inputs, you need to wait 10 seconds
and then perform SERVO ON.
Note
The range of electronic gear ratio is from 0.02 to 200.
The electronic gear ratio can be set only at SERVO OFF state. After the setting, you need to
reference the drive again.
Содержание SIMOTICS S-1FL6
Страница 1: ...SINAMICS V90 SIMOTICS S 1FL6 ...
Страница 2: ......
Страница 87: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 85 ...
Страница 89: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 87 ...
Страница 342: ...Tuning 9 9 PI P switching SINAMICS V90 SIMOTICS S 1FL6 340 Operating Instructions 04 2019 A5E36037884 007 ...
Страница 384: ...Parameters 10 2 Parameter list SINAMICS V90 SIMOTICS S 1FL6 382 Operating Instructions 04 2019 A5E36037884 007 ...
Страница 432: ......